VISTA-120 Installation and Setup Guide
4-4
Zone Index
The VISTA-120 has 128 physical zones, as well as
supervisory zones for relays, ECP devices (devices
which communicate through the keypad terminals), and
system troubles.
The zones are designated as follows:
Zone
Function
1
2-wire Smoke Detectors (if used)
5
Audio Alarm Verification (if used)
7
Keyswitch (if used)
8
Latching-Type Glassbreak Detectors (if used)
1-9
Basic Wired Zones
1-128
5800 Series Wireless Devices
10-128 Polling
Loop
Devices
995
✳
+ 1 Panic
996
# + 3 Panic
999
✳
+ # Panic
ZONE #
RANGE
ZONE
FUNCTION
ACTUAL ZONE
001 - 128
Protection
zones
As indicated
601 – 696
Relay
Supervisory
Zones
6 + 2-digit relay number (e.g.
relay number 03, if
supervised, is zone 603
NOTE: Relay supervision
should be used only for
relays on 4204CF modules.
800 - 830
ECP Device
Supervisory
Zones
8 + 2-digit Device Address,
e.g., Device Address 01, if
supervised, is zone 801. The
4286 VIP module is zone 804
(since its Device Address must
be set to 4).
988, 990, &
997
System
Supervisory
Zones
988: 2
nd
Wireless Receiver –
not receiving signals
990: 1
st
Wireless Receiver –
not receiving signals
997:
Polling Loop (short
circuit)
995, 996,
999
Keypad
Panics
995: 1+
✴
panic (A key)
996: 3 + # panic (C key)
999:
✴
+ # panic (B key)
Communication Programming Guide
Field #
Low Speed
Contact ID
High Speed
Express
*46, *48
Choose transmission speed and
frequency
No effect
No effect
No effect
*52, *53
Send as either 4+2 or expanded
No effect
No effect
No effect
*79, *80
Enables alarm restores
Enables alarm
restores
Enables alarm restores
Enables alarm restores
*49
Add checksum digit
No effect
Add checksum digit
No effect
*50
Sescoa/Radionics. Selects fixed digit
time instead of fixed interdigit.
No effect
No effect
No effect
NOTE:
Low Speed will
not
send 3+2 messages. Zone ID digit is suppressed.
Communication Defaults
*45 PRIMARY FORMAT
[1]
ADEMCO Contact ID
*46
LOW SPEED FORMAT (Prim) [0]
ADEMCO Low Speed
*47 SECONDARY FORMAT
[1]
ADEMCO Contact ID
*48 LOW SPEED FORMAT (Sec.) [0]
ADEMCO Low Speed
*49 CHECKSUM VERIFICATION [0] [0]
No
checksum
Primary
Secondary
*50 SESCOA/RADIONICS SEL.
[0]
Radionics
*51 DUAL REPORTING
[0]
no
*52
STANDARD/EXPANDED REPORT FOR PRIMARY
[0] [0] [0] [0] [0]
[0]
standard
Alarm Rstr Bypass
Trbl Opn/Cls Low Bat
*53 STANDARD/EXPANDED REPORT FOR SECONDARY
[0] [0] [0] [0] [0]
[0]
standard
Alarm Rstr Bypass
Trbl Opn/Cls Low Bat
Summary of Contents for ADEMCO VISTA-120
Page 2: ...ii ...
Page 18: ...VISTA 120 Installation and Setup Guide 2 8 ...
Page 70: ...VISTA 120 Installation and Setup Guide 5 16 ...
Page 88: ...VISTA 120 Installation and Setup Guide 7 4 ...
Page 90: ...VISTA 120 Installation and Setup Guide 8 2 ...
Page 100: ...VISTA 120 Installation and Setup Guide A 2 ...
Page 104: ......
Page 106: ......
Page 113: ......