Section 3 – Installing the Control
3-9
Wireless (RF) Zone Expansion
The VISTA-120 supports wireless zones that may be
used exclusively or in addition to basic wired and/or
polling loop zones. The system supports the 5800 series
RF system using the following receivers:
5800 Series
5800EU Series
Rcvr Zones Rcvr Zones
5881ENL
up to 8
5882EU
up to 128
5881ENM
up to 16
5882AP
up to 128
5881ENH
up to 128 5882EUH
up to 128
Wireless System Operation and Supervision
•
The receiver responds to status and alarm signals
from wireless transmitters [345 MHz (5800 series),
315MHz (5800AP series), 433.92MHz (5800EU
series), and 868.095 MHz (5800H series)] within a
nominal range of 60m, and relays this information
to the control.
•
Each 315/345MHz supervised transmitter sends a
supervisory signal to the receiver every 70-90
minutes (433.92MHz transmitters transmit every
23-26 minutes and 868.095 MHz transmitters
transmit every 9 minutes).
If, after a programmed interval of time (e.g., 24 or 2
hrs), the receiver does not hear from a
particular
transmitter, the word CHECK or TRBL will appear
at the corresponding partition's keypad(s)
accompanied by the zone number.
The trouble will not prevent you from arming the
panel, as long as the zone is first bypassed.
•
If, within a programmed interval of time (e.g., 24 or
2 hrs), the receiver does not hear from
any
of its
transmitters, a CHECK or TRBL message appears
for zones 988 (2nd receiver) or 990 (1st receiver) if
zone type 05 is assigned to these supervisory zones.
This may be an indication that the wireless
receiver is not able to "hear" signals. The same
indications are provided if the 5882EU/5882EUH
transceiver detects that it is being jammed by a
source of RF energy that is present for 30 seconds
within any 60-second interval.
•
The control checks the receiver connections about
every 45 seconds. If the panel has lost
communication with the receiver, a CHECK or
TRBL message will appear for the receiver zone
number (8xx, where xx = receiver's device address)
if type 05 is assigned to these supervisory zones.
This may be an indication that the wiring to the
receiver is incorrect, or that the DIP switches are
not set for the same address the receiver was
assigned to in the panel's Device Programming
mode.
•
Two identical receivers can be used to provide
either a greater area of coverage, or to provide
redundant protection.
•
Any zone from 1-128 can be used as a wireless
zone, with the exception of zone 64 (reserved for a
wireless keypad).
Wireless System Installation Advisories
•
Place the receiver in a high, centrally located area
for best reception. Do not place receiver on or near
metal objects. This will decrease the range and/or
block transmissions. Do not mount receivers or
transmitters in an attic, where extreme
temperatures could prevent proper operation.
•
For maximum range, install the wireless receiver
at least 3 metres from the Control panel or any
keypads to avoid interference from the
microprocessors in these units.
•
If dual receivers are used:
a.
Both must be at least 3m from each other, as
well as from the Control panel and remote
keypads.
b.
Each receiver must be set to a different Device
Address (01-07). The receiver set to the lower
address is considered the 1st wireless receiver
for supervisory purposes.
c.
The house IDs must be the same if using a
5827/5827AP/5827BD wireless keypad.
d.
Using two Receivers
does not
increase the
number of transmitters the system can
support.
Installation and Setup of the 5881EN/5882EU/5882AP
Wireless Receivers
1.
Mount the receiver(s). Receivers must be mounted
externally to the control and can detect signals
from transmitters within a nominal range of 60m.
Take this into consideration when determining
mounting location.
2.
Connect the receiver's wire harness to the control's
keypad terminals (6, 7, 8, and 9). Plug the
connector at the other end of the harness into the
receiver.
3.
Refer to the installation instructions provided with
the receiver for further installation procedures
regarding antenna mounting, etc.
4.
Set the receiver's DIP switches for an address (01-
07) which is not being used by another device (i.e.,
keypads, relay modules, etc.).
TO CONTROL'S REMOTE KEYPAD
CONNECTION POINTS.
USE MAX. of 67m of #22 (0.64mm)
WIRE or 168m of #18 (1mm) WIRE
FOR EACH RUN.
(SEE RECEIVER'S INSTRUCTIONS.)
DIP SWITCH WHITE AREAS = SWITCH
HANDLES. POSITION 2-4 DETERMINE
RECEIVER'S ADDRESS. CONSULT
CONTROL'S INSTRUCTIONS FOR
ADDRESS TO USE. DIP SWITCH BELOW
SHOWN SET FOR ADDRESS "0."
SWITCH
POSITION
RECEIVER ADDRESS SETTINGS
(" - " MEANS OFF)
0 1 2 3 4 5 6 7
4
3
2
1
5
PRESENT ONLY ON 5881EH (SEE TEXT AT LEFT)
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
FOR FUTURE USE
DIP SWITCH #5 (PRESET ONLY ON 5881EH)
ON
: SETS 5881EH FOR USE IN COMMERCIAL
FIRE APPLICATIONS (SEE THE RECEIVER'S
INSTRUCTIONS).
OFF
: USE IN NON-COMMERCIAL FIRE
INSTALLATIONS.
MOUNTING
HOLES
INSERT IN
RIGHT-HAND
TERMINALS
CIRCUIT
BOARD
DIP SWITCH
YELLOW
RED
BLACK
GREEN
INTERFERENCE
INDICATOR LED
WIRING
OPENING
PLUG & SOCKET
ANTENNAS
5881-001-V2
Figure 3-17. 5881EN/5882AP Wireless Receiver
Summary of Contents for ADEMCO VISTA-120
Page 2: ...ii ...
Page 18: ...VISTA 120 Installation and Setup Guide 2 8 ...
Page 70: ...VISTA 120 Installation and Setup Guide 5 16 ...
Page 88: ...VISTA 120 Installation and Setup Guide 7 4 ...
Page 90: ...VISTA 120 Installation and Setup Guide 8 2 ...
Page 100: ...VISTA 120 Installation and Setup Guide A 2 ...
Page 104: ......
Page 106: ......
Page 113: ......