Specifications
ACUIX Housings
Table B-1
Housing Specifications
Specification
Indoor Pendant Housing
Outdoor Pendant
Housing
In-ceiling Housing
Housing Height
7.5 in. (190.5 mm)
7.5 in. (190.5 mm)
6.7 in. (170.21 mm)
Housing Diameter
9.25 in. (235 mm)
10.0 in. (254 mm)
8.13 in. (206.45 mm)
Housing Flange Diameter
9.25 in. (235 mm)
9.25 in. (235 mm)
8.0 in. (203.2 mm)
Housing Material
Aluminum
Aluminum
Aluminum
Lower Dome Diameter
7.5 in. (191 mm)
7.5 in. (191 mm)
7.5 in. (191 mm)
Lower Dome Material
Acrylic and Polycarbonate
Acrylic and Polycarbonate
Acrylic and Polycarbonate
Mounting Method
1.5” NPT
1.5” NPT
1.5" NPT
IP Rating
--
IP66
--
NEMA Rating
--
NEMA 4X
--
Operating Voltage
24 VAC ± 10%
24 VAC ± 10%
24 VAC ± 10%
Operating Current
1.9A
2.5A
1.9A
Operating Temperature
0° to 50°C
(32° to 122°F)
-40° to 50°C
(-40° to 122°F)
0° to 50°C
(32° to 122°F)
Operating Humidity
0 to 95%, non-condensing
0 to 95%, non-condensing
0 to 95%, non-condensing
Storage Temperature
-40° to +60°C
(-40° to +140°F)
-40° to +60°C
(-40° to +140°F)
-40° to +60°C
(-40° to +140°F)
Summary of Contents for ACUIX
Page 1: ...Document 800 01023 Rev A 02 08 User Manual ACUIX High Speed Dome ...
Page 10: ...Rev A Document 800 01023 02 08 Contents 10 ...
Page 12: ...Rev A Document 800 01023 02 08 Figures 12 ...
Page 28: ...28 Switch Settings ...
Page 74: ...74 Operation and Programming with Honeywell VCL Protocol ...
Page 78: ...78 Operation and Programming with IntelliBus Protocol ...
Page 132: ...132 Troubleshooting ...
Page 138: ...138 Specifications ...
Page 140: ...140 Pelco Emulation ...
Page 142: ...142 Digital Video Recorder Integration ...
Page 147: ......