Baud Rate
DIP SW6, position 1 through 4 are used to set the baud rate. The baud rate of the ACUIX
and the control equipment must be the same.
Note
If there are invalid settings on SW5 or SW6 regarding protocol or baud rate,
the system defaults to Diamond protocol at 9600 baud rate.
Table 2-2
DIP Switch SW6 ACUIX Baud Rate Settings
Baud Rate
Switch Position
1
2
3
4
600
OFF
OFF
OFF
OFF
1200
ON
OFF
OFF
OFF
2400
OFF
ON
OFF
OFF
4800
ON
ON
OFF
OFF
9600
OFF
OFF
ON
OFF
19200
ON
OFF
ON
OFF
38400
OFF
ON
ON
OFF
57600
ON
ON
ON
OFF
115200
OFF
OFF
OFF
ON