Current consumption of the devices in the example:
contactless / proximity reader (026390.10)
70mA
4I/2O-module (026592)
230mA
door strike
230mA
Calculation of the line cross-section with 40m cable length:
The required line cross-section can be determined from diagram 1 or 2 (page 30/31).
The maximum voltage drop of the line is 0.5V. If the ACS-8 is not equipped with a battery, a voltage drop
of 2V-3V is possible. This means that smaller cross-sections can be used if the length is kept constant or
longer lengths can be used if the cross-section is kept constant.
Module supply:
Total current consumption of the modules:
contactless / proximity reader (026390.10)
70mA
4I/2O-module (026592)
230mA
total:
300mA
Calculation of the maximum line resistance:
R
L
=
Uv
=
500mV =
1.67
Ω
I
300mA
Calculation of the required cross-section:
i
=
electrical conductivity = 56m
of copper
Ω
mm²
A
=
2 x L
=
2 x 40m
=
0.855mm
²
R
L
x
i
1.67
Ω
* 56m
Ω
mm²
Calculation of the number of wires with a wire cross-section of 0.28mm² (Ø 0.6mm):
no. of wires
=
0.855mm²
=
3.05 wires
!
3 wires
0.28mm²
Calculation of the number of wires with a wire cross-section of 0.5mm² (diameter 0.8mm):
no of wires
=
0.855mm²
= 1.71 wires
!
2 wires
0.5mm²
Summary of Contents for ACS-8
Page 2: ... VdS Approval Z 105009 class C ...
Page 16: ...16 Installation Instructions ACS 8 ...
Page 28: ...28 Installation Instructions ACS 8 ...
Page 29: ...Installation Instructions ACS 8 29 ...
Page 76: ...76 Installation Instructions ACS 8 Connection component mounting diagram ...
Page 92: ...92 Installation Instructions ACS 8 15 2 ACS 8 Structure ...
Page 122: ...122 Installation Instructions ACS 8 Connection diagram for 026064 Keypad sm plastic housing ...
Page 123: ...Installation Instructions ACS 8 123 ...
Page 124: ...124 Installation Instructions ACS 8 ...
Page 130: ...130 Installation Instructions ACS 8 ...
Page 140: ...140 Installation Instructions ACS 8 ...