102
OPERATION
(Display Assy type)
Some indicator and/or buzzer will be activated at the same time due to the occurrence of a malfunction.
*: Refer to 105 page about power reduction.
System
Symptom
INDICATOR
BUZZER
WARNING
LEVEL
Power
Reduction*
Oil pressure
(Red)
Overheat
(Red)
ACG
(Red)
PGM-FI
(Red)
CORRESPONDING
SYSTEM
During operation
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Low oil pressure
ON
OFF
OFF
OFF
ON (continuously)
ON
Overheat
OFF
ON
OFF
OFF
ON (continuously)
ON
ACG warning
OFF
OFF
ON
OFF
alternating ON and OFF
(at long intervals)
OFF
PGM-FI warning
OFF
OFF
OFF
ON
alternating ON and OFF
(at long intervals)
OFF
Water contamination
OFF
OFF
OFF
OFF
alternating ON and OFF
(at short intervals)
OFF
Warning level 1
Warning level 1
Warning level 2
Warning level 2
Warning level 2
42ZVL600.book 102 ページ 2018年7月19日 木曜日 午前9時6分