10.15. TECHNICAL DETAILS
The following is offered as a general guide to values and capacities commonly used.
HP / RPM
Resistance Readings (ohms)
Pump Weight
230V / 1Ph
230V / 3Ph*
460V / 3Ph*
U1 - U2 / U1 - Z2
U-V-W
U-V-W
2.5HP / 1750 D
2.2 / 5.0
1.5
5.0
230 lbs / 104 kg
2.8HP / 1160 T
N/A
2.7
5.0
230 lbs / 104 kg
2.9HP / 1750 N
2.2 / 5.0
3.1
11.0
230 lbs / 104 kg
2.9HP / 1750 T
3.1
11.0
230 lbs / 104 kg
3.5HP / 1750 D
N/A
1.9
5.5
230 lbs / 104 kg
3.8HP / 1160 T
N/A
1.5
2.5
240 lbs / 108 kg
4.3HP / 1750 N
1.5 / 3.0
1.5
4.2
240 lbs / 108 kg
4.3HP / 1750 T
1.5
4.2
240 lbs / 108 kg
5.1HP / 1750 T
1.1 / 2.6
N/A
N/A
250 lbs / 113 kg
5.5HP / 1750 N
/ 1.9
1.3
3.7
250 lbs / 113 kg
5.5HP / 1750 T
N/A
1.3
3.7
250 lbs / 113 kg
6.2HP / 1160 T
N/A
1.3
3.7
250 lbs / 113 kg
6.7HP / 1750 T
0.7 / 1.9
N/A
N/A
260 lbs / 118 kg
7.5HP / 1750 N
/ 1.5
0.9
2.6
260 lbs / 118 kg
7.5HP / 1750 T
N/A
1.2
3.0
260 lbs / 118 kg
8.3HP / 1160 T
N/A
0.9
2.6
260 lbs / 118 kg
9.7HP / 1750 T
0.5 / 1.4
N/A
N/A
260 lbs / 118 kg
9.8HP / 1160 P
N/A
0.7
2.2
290 lbs / 132 kg
10HP / 1750 N
0.3 / 0.9
0.6
1.9
290 lbs / 132 kg
10HP / 1750 T
N/A
0.6
1.9
290 lbs / 132 kg
11.4HP / 1750 T
0.4 / 0.8
N/A
N/A
290 lbs / 132 kg
13HP / 1750 P
N/A
0.5
1.8
350 lbs / 159 kg
15.3HP / 1160 P
N/A
0.5
1.1
350 lbs / 159 kg
20HP / 1750 P
N/A
0.5
1.1
400 lbs / 181 kg
21.5HP / 1160 P
N/A
0.5
1.1
400 lbs / 181 kg
29HP / 1750 P
N/A
0.4
0.7
500 lbs / 227 kg
*Values should be as indicated between any 2 power leads.
Resistance values include 30’cable, and should be /- 10% of above value.
Above 30 HP, resistance values between 230 and 460 volt machines very by less than 0.1 ohm. Consult factory with
specific requirements.
Impeller Bolt Torque:
10mm – 26ft lb / 35Nm, 12mm – 45ft lb / 61Nm, 16mm – 108ft lb / 146Nm, 20mm – 210 ft lb / 285Nm
Impeller to Bottom Plate Clearance:
(ASC) .020” / 0,3mm minimum clearance.
Pump Rotation:
Right hand (CW) looking down from top of motor, CCW looking at bottom of pump.
Seal Probes:
N motor pumps use a 12mm seal probe P motor pumps use 20mm seal probe.
Single wire probes are for non-classified areas, and 2 wire probes are for Hazardous areas.