HV350 Mini Frequency Inverter User Manual
25
SET key
to enter and view the parameter; press
PRG
key to exit; and press
►►
key to
scroll through parameters in stopping state.
4.4.3
Running state
In stopping state, after receiving running command, the drive enters running
state. The LED and unit indicator display parameter and its unit respectively.
At this time, running status indicator is ON all the time. Press PRG key to
enter programming menu and view parameter value.
Press ►► key, LED displays running parameter ―r-xx‖ (xx=00~15). Press
SET key to enter and view parameter value; press PRG key to exit this parameter
menu; press ►► key to scroll through monitoring parameters.
4.4.4
Fault alarm state
In stopping, running or programming state, correspondent fault information
will be reported if fault is detected. At this time, LED displays the fault code in
flashing mode. When fault alarm occurs, press PRG key to enter programming
menu and look up the fault log.
When fault alarm occurs, the alarm picture is displayed, and the fault can be
reset by press STOP/RESET key. The drive restores to normal operation upon
clearing the fault, and the fault code is displayed again if the fault has not been
cleared.
4.5 Panel Operation Method
4.5.1
Panel Operation Procedure
Parameter setting method via panel: through three-level menu, users can look
up and modify the function codes very easily.
Three level menu structure: function parameters (first level)
→
function
codes(second level)
→
value of function code(third level). Operation process is
shown in Fig.4-1.