HV350 Mini Frequency Inverter User Manual
32
setting
P0.12
Rotating
direction
(Keypad operation)
0: FWD
1: REV
0
12
+
P0.13
Maximum
output
frequency
50.00~400.0 Hz
50.00
13
+
P0.14
High frequency limit
0.00~ Maximum output frequency
50.00
14
+
P0.15
Low frequency limit
0.00Hz~ High frequency limit
0
15
+
P0.16
Acc time 1
0.1~3600.0s
20.0
16
#
P0.17
Dec time 1
0.1~3600.0s
20.0
17
#
P0.18
reserved
0
18
+
P0.19
Parameter
initialization
0: No operation
1: Clear fault information
2: Recover factory setting
Note: After executing 1~2 steps, restores to
zero automatically.
0
19
+
P1 Group
Auxiliary function parameters 1
P1.00
Starting mode
0: Start from starting frequency
1: First braking then restart from starting
frequency
0
20
+
P1.01
Starting frequency
0.50~20.00Hz
0.50
21
+
P1.02
Hold time of Starting
Frequency
0.0~60.0s
0
22
+
P1.03
DC injection braking time
at start
0.0~60.0s
0
23
+
P1.04
DC
injection
braking
current start
0.0~100.0%(motor rated current)
0
24
+
P1.05
Stopping mode
0: Dec-to-stop
1: Dec-to-stop + DC braking
2: Free run to stop
0
25
+
P1.06
Initial frequency of
0.00~20.00Hz
0
26
+