Used to select buzzer options for panel events.
When
MainFlt Buz
is enabled the Rkp buzzers will sound
every 4 seconds (in addition to a visual indication) during a
power cut and if the panel is unset. If this option is disabled
then there will only be a visual indication.
When
Line Flt Buz
is enabled then the Rkp buzzers will sound
once every 4 seconds indicating a line fault condition similar to
the
Mains Flt Buz
option.
When
FTC Buzzer
is enabled the Rkp
buzzers will sound
every 4 seconds
(and have
a visual indication
)
in the event of
the dialler failing
to communicate
after 3 attempts.
Note:
that “FTC” is shorthand for Failed to Communicate
With the restricted indication option selected, you may not want
to depend on just the LEDs to inform the end user of faults. In
this case set
Fault Alert Buzzer
to YES for an additional
audible alert.
87 AUDIO OPTIONS
871 MainsFlt Buz
872 Line Flt Buz
873 FTC Buzzer
874 Fault Alert Buzzer
System Options Menu - Continued
!
Default Eng. Code - 4567 Default User Code - 1111 (Irl) 1234 (UK)
85