33 ZONE OPTIONS
Zone options enable further control of a zone
programmed with a particular type.
For instance, a zone programmed with the type
Alarm
can have the
Excl PsA
option enabled.
This will exclude the zone from the system
when part set A has been selected. This is
effectively an automatic inhibit.
Refer to table
below to see which Options can be associated
with which Zone Types.
Zone Menu- Continued
Default Eng. Code - 4567 Default User Code - 1111 (Irl) 1234 (UK)
63
ShuntLck (shorthand for Shunt Lock) is a special input for BS 8243 installations. Sections
6.3 and 6.4 of the standard allows for the use of a shunt lock fitted to the final exit door. The
setting procedure is a two-stage process i.e. using the User Code to start the arming
process within the supervised premises followed by completion i.e. locking the final door
with a shunt lock.
The Shunt Lock zone has an option called “Unset”. If this option is set to YES, it means that
as soon as the entry door is unlocked the system is unset (or disarmed). If it is programmed
to be NO then the Shunt Lock automatically becomes an Entry/Exit zone and the system is
prohibited from triggering a verified alarm. See page 114 & 115 for more details
Shunt Lock
Inhibit
Access
Excl. from Part Set A
Excl. from Part Set B
Double Knock
Soak
Chime
24 Hour
Perimeter
Remote Test
Inhibit
Excl. from Part Set A
Excl. from Part Set B
Soak
Chime
Disable BV
Remote Test
Inhibit
Soak
Silent PA
Remote Test
Inhibit
Soak
Remote Test
Soak
Key Pulse
Remote Test
Inhibit
Soak
24 Hour
Fire Exit Delay
Remote Test
None
Remote Test
Unset
Remote Test
Inhibit
Soak
24 Hour
Remote Test
ZONE/POINT TYPES vs OPTIONS
Alarm
Entry / Exit
Panic
Fire
Tamper
Gas
Key
Key Partset A
Key Partset B
Fire Exit
Exit Terminator
Shunt Lock
Line Fault
Fail To Communicate
Technical
ZONE 2
ZONE 4