Zone Wiring
DUAL END OF LINE WIRING 4K7
DUAL END OF LINE WIRING 2K2
Single Detector e.g. PIR with only 4-core cable
Single Detector e.g. PIR with only 4-core cable
Most commonly used within the industry
Usually for retrofit in a previous EOL system
Note: Requires only 2 wires (+ 2 power for PIR)
Note: Requires only 2 wires (+ 2 power for PIR)
SENSORS 1.. 10
SENSORS 1.. 10
TAMPERS 1.. 10
TAMPERS 1.. 10
4K7
4K7
RED
RED
RED
RED
BLACK
BLACK
BLACK
BLACK
YELLOW
YELLOW
YELLOW
YELLOW
Multiple Detectors e.g. Inertia Sensors
Multiple Detectors e.g. Inertia Sensors
Note: Additional return wire required
Note: Additional return wire required
4K7
2K2
2K2
2K2
2K2
4K7
RED
RED
YELLOW
YELLOW
ALARM
ALARM
TAMPER
TAMPER
STANDARD Non-EOL WIRING
SINGLE END OF LINE WIRING
SENSORS 1.. 10
TAMPERS 1.. 10
RED
BLUE
BLACK
YELLOW
SENSORS 1.. 10
TAMPERS 1.. 10
4K7
RED
BLUE
BLACK
YELLOW
ZONE 1 T
AMPER 1
ZONE 1 T
AMPER 1
ZONE 1 T
AMPER 1
ZONE 1 T
AMPER 1
ZONE 1 T
AMPER 1
ZONE 1 T
AMPER 1
Default Eng. Code - 4567 Default User Code - 1111 (Irl) 1234 (UK)
Your SW-1070 Control Panel comes with a minimum of 10 hardwired zone inputs -
Zone 1 to 10
.
By default these are shipped as a non-EOL (end-of-line) input (or Dual EOL 4K7 inputs in the UK).
•
The other EOL options are Single EOL, Dual EOL 4K7 and Dual EOL 2K2. See the wiring diagrams below.
• If you have already mapped a wireless detector on to Zone 1 it cannot be used as a hardwired input unless
you remove that wireless device and map it on to another zone number instead.
•
1
Zone Names
2
Zone Types
3
Zone Options
4
Zone Gross & Pulse
5
Zone Hardware
6
Zone Block Assign
7
Technical Zone Options
8
Zone Map Menu
01
Non EOL
02
Single EOL
03
Dual EOL 4K7
0X
Point ID
0X
RF Device
0X
RFI Device
0X
Dual EOL 2K2
2
Devices Menu
1
Service Menu
3
Zone Menu
45