SW-1070 Panel / Power Supply Unit
Default Eng. Code - 4567 Default User Code - 1111 (Irl) 1234 (UK)
51
NOTE:
Please ensure that zone
terminals are linked as shown.
NOTE:
Max. cable run to Power Supply = 200m
A total of 600m of cable can be used.
!
!
Aux 12V Remote Keypad
+
+
B
-
-
A
Point
ID Bus
Point
ID Bus
Point
ID Bus
Point
ID Bus
}
}
}
}
ZONE 5
ZONE 6
ZONE 7
ZONE 8
ZONE 9
ZONE 10
0V
NC
NC
NO
NO
C
C
12V
12V
12V
-
-
+
+
TAMPER
DA
T
A
OUTPUT 1 OUTPUT 2
Tamper
Switch
Position PS51
You can convert some of your hardwired zones (zones 5, 6, 7 & 8) into Point ID buses. This allows you to wire-
in a maximum of five Power Supplies per ID bus (i.e. twenty in total)
• Wire-up zone (see wiring example below).
•
,
•
In engineer mode scroll to the
Zone Menu
. Press YES and scroll to
Zone Hardware
. Press YES again. Scroll down to
the zone you are interested in (e.g. in the wiring examples below you would select zone 5 and 6).
Scroll to
Point ID
. Then press YES.
The system will automatically check the data bus for all Output Cards. When the
scanning finishes, quit from this branch of the menu....
1
Zone Names
2
Zone Types
3
Zone Options
4
Zone Gross & Pulse
5
Zone Hardware
6
Zone Block Assign
7
Technical Zone Options
8
Zone Power Supply Assign
9
Zone Map Menu
2
Devices Menu
1
Service Menu
3
Zone Menu
1
Non EOL
2
Single EOL
3
Dual EOL 4K7
4
Point ID
5
RF Device