2
Mapped Output Options
2
Pulsed Output
3
Latched Output
4
Output Trip Time
NO
NO
NO
2s
1
Mapped Outputs
1
Unset Disable
Z001 GROUP #01
Z001 GROUP #01
Z001 To Z001
.. .. ..
Z069 No Output
Z070 No Output
• Go to
Zone Menu
and press YES. Scroll to
Zone Map Menu
and press YES.
• You will see
Mapped Outputs
on the display. Scroll to
Mapped O/P Opts
and press YES.
• Following on from the example on the previous page you will see
Z001GROUP #01
on the display. Pressing
YES brings
Z001 To Z001
to the display. For this example, press YES.
• First up is
Unset Disable NO
. If you change to
YES
the outputs in group 1 will not trigger when the system
is in the unset state.
• Next option is
Pulsed O/P NO
. If you change this to
YES
the outputs in group 1 will activate for a few
seconds (see
O/P Trip Time
below)
• Next option is
Latched O/P NO
. If you change this to
YES
the outputs in group 1 will activate and stay
activated until the system is unset (or if already in an unset state, the system is armed and then unset).
• Finally,
O/P Trip Time
is where you can adjust the pulse time. Normally this is 2 seconds but can be
programmed to be up to 99 seconds.
NOTE:
If you leave both
Pulsed O/P
and
Latched O/P
options set to
NO
then the outputs simply follow
the status of its zone. In this example, if zone 1 is open the outputs in group 1 trigger and when it is
closed they are not triggered.
!
Outputs Menu - Continued
Default Eng. Code - 4567 Default User Code - 1111 (Irl) 1234 (UK)
79
User Outputs are special outputs that can be controlled by the user if they send certain commands to the
system via an SMS text message (or, alternatively by using the
0*8
Quick Key command on page 76).
74 O/P CARD OUTPUTS
76 USER OUTPUTS
75 OUTPUT GROUPS
Example: Programming a User Output on one of the Panel outputs.
•
Go to
Outputs Menu
and select YES.
•
Panel Outputs
will be on the display. Again, press YES.
You should see
01 Pre Alrm +
on the display. Press YES or scroll to another output and then press YES.
In this example
Pre Alrm
(shorthand for Pre-Alarm)
will flash on the display.
You can now scroll & select a User Output type from this list:
Pulse Gate
,
Heat
,
Gates
,
Aux
&
Free to use
.
For the example below, select
Free to use
.
See bottom half of page 77 for how the various User Outputs work.
Once you have selected your output type you will be prompted to select between negative or positive.
You can use any of the 4 User Outputs. So for instance, follow the menu below & scroll to
OP4 Free to use
The
4
will be flashing. Press YES. You can now type in a new command e.g.
PUMP
. Again, press YES.
OP4 PUMP
will be on the display. The user can now send their user code followed by a space and then the
phrase
PUMP ON
to trigger output 1 on the panel.
•
•
•
•
•
•
•
•
•
•
There is one User Output Option i.e.
Pulse Gate 05s
. Adjust this value to suit your particular gate controller
2
Output Options
OP2 Gates
OP4 Free to use
1
Output Names
OP1 Heat
1
Pulse Gate 05s
OP3 Aux
7
Outputs Menu
6
Timers Menu
8
System Options
3
PSU Outputs
4
Output Card Outputs
6
User Outputs
5
Output Groups