NOTE:
Please ensure that
zone terminal is
linked as shown.
Up to 10 points
can be connected
to a zone.
NOTE:
Please ensure
that sensor head
arrow is vertical
before fitting lid
BLACK
BLACK
BLUE
BLUE
BLACK
RED
RED
RED
Point ID Sensors
SENSOR 1
SENSOR 10
CONTACT
TAMPERS
BLACK
BLACK
BLUE
BLUE
BLUE
RED
RED
SENSOR 10
SENSOR 1
REED VERSION
Adding standard
senors and
contacts
Tamper Switch
Status LED
NOTE:
Max. cable run to ID sensor = 200m
A total of 600m of cable can be used.
Alternatively, you can convert your hardwired zone input into a Point ID bus. This allows you to wire-in a
maximum of ten Point ID sensors per zone.
• Wire-up zone (see wiring example below).
• Leave the covers of the sensors off for now
•
,
Point ID sensors
In engineer mode scroll to the
Zone Menu
. Press
YES
and scroll to
Zone Hardware
. Press
YES
again. Scroll down
to
Point ID
. Then press
YES.
The system will automatically check the data bus for all
. When the
scanning finishes, quit from this branch of the menu....
Default Eng. Code - 4567 Default User Code - 1111 (Irl) 1234 (UK)
!
!
!
1
Zone Names
2
Zone Types
3
Zone Options
4
Zone Gross & Pulse
5
Zone Hardware
6
Zone Block Assign
7
Technical Zone Options
8
Zone Map Menu
01
Non EOL
02
Single EOL
03
Dual EOL 4K7
0X
Point ID
0X
RF Device
0X
RFI Device
0X
Dual EOL 2K2
2
Devices Menu
1
Service Menu
3
Zone Menu
Aux
12V
REMOTE RKP/EXP
+
+
B
-
- A