50
Default Eng. Code - 4567 Default User Code - 1111 (Irl) 1234 (UK)
SW-1070 Panel / 10-Zone Expander - continued
Example: Adding a 10-Zone Expander in position Exp1.
•
•
•
Go to
Devices Menu
and select YES. Scroll to
Wired Devices Menu
and press YES. Then select
Add & Id
Devices
Add & Id:Keypads
will be on the display. Scroll to
Add & Id:Expandr
and press YES.
Scanning Expandr
will be on the display. When prompted, close the tamper switch on the 10-Zone Expander
The 1st 10-Zone Expander has now been added to the system in location Exp1. The system is now ready to
accept the 2nd 10-Zone Expander in location Exp2 and so on.
2
Devices Menu
2
Devices Menu
2
Wired Devices Menu
2
External Bell -ve
2
Wired Devices Menu
1
RF Devices Menu
1
Internal Bell -ve
1
RF Devices Menu
1
Add & ID Devices
1
Add & ID Devices
1
Add & ID: Keypads
1
Locate : Keypads
1
EXP 1 Outputs
2
Add & ID: Z5 Devices
2
Locate : Z5 Devices
.. .. .. ..
3
Add & ID: Z6 Devices
3
Locate : Z6 Devices
13
EXP 13 Outputs
4
Add & ID: Z7 Devices
4
Locate : Z7 Devices
5
Add & ID: Z8 Devices
5
Locate : Z8 Devices
6
Add & ID: Expanders
6
Locate : Expanders
2
Locate Devices
2
Locate Devices
3
Remove Devices
3
Remove Devices
1
Service Menu
1
Service Menu
3
Zone Menu
3
Zone Menu
Example: Programming the outputs on the 10-Zone Expander Exp1.
•
Go to
Outputs Menu
and select YES.
•
Scroll to
Expander Outputs
and press YES.
You should see
EXP1 Outputs
on the display. Press YES or scroll to another expander.
01 Int. Bell -
will be on the display. Either press YES or scroll to
02 Ext. Bell -
and press YES.
You can now select an output type from the list on page 75.
Once you have selected your output type you will be prompted to select between negative or positive polarity.
•
•
•
•
Example: Locating the 10-Zone Expander Exp1 & Exp2.
•
Go to
Devices Menu
and select YES. Scroll to
Wired Devices Menu
and press YES. Then select
Locate
Devices
•
Press YES.
Locate :Keypads
will be on the display. Scroll to
Locate : Expanders
and Press YES.
•
After a short while
Exp1 Exp1
will be on the display and the status LED 10-Zone Expander number 1will be
flashing on and off every second.
•
Pressing NEXT will bring you on to
Exp2 Exp2
. Now the status LED on the 10-Zone Expander number 2 will
start flashing on and off every second.
7
Outputs Menu
3
PSU Outputs
6
Timers Menu
1
Panel Outputs
2
Expander Outputs
8
System Options
4
Output Card Outputs
5
Output Groups