52
Default Eng. Code - 4567 Default User Code - 1111 (Irl) 1234 (UK)
SW-1070 Panel / Power Supply Unit - continued
Example: Adding a Power Supply in position 51.
•
•
•
•
•
•
Go to
Devices Menu
and select YES. Scroll to
Wired Devices Menu
and press YES. Then select
Add & Id
Devices
Add & Id:Keypads
will be on the display. Scroll to
Add & Id:Z5 Devs
.
This is shorthand for: Add and identify
devices on zone 5's data bus.
Press YES.
Add & Id:P50..59
will be on the display. Scroll to
Add & Id:PS51.55
.
This is shorthand for: Add and identify
any power supply on zone 5's data bus and name them Power Supply 51, Power Supply 52 etc.
Press YES.
When prompted, close the tamper switch on the Power Supply. The 1st Power Supply has now been added to
the system in location PS51. The system is now ready to accept the 2nd Power Supply in location PS52 and so
on.
Example: Locating Power Supply in position 51.
•
•
•
•
Go to
Devices Menu
and select YES. Scroll to
Wired Devices Menu
and press YES. Then select
Locate
Devices
Locate:Keypads
will be on the display. Scroll to
Locate:Z5 Devs
. Press YES.
Locate:P50..59
will be on the display. Scroll to
Locate:PS51.55
. Press YES.
PS51 PSUNumber51
will be on the display and the Fault LED on the front of Power Supply 51 will be flashing
on and off every second. Pressing NEXT brings to Power Supply 52 and so on.
Example: Programming output number 1 on output card PS51.
•
•
•
•
Go to
Outputs Menu
and select YES. Scroll to
Psu Outputs
and press YES.
Psu is shorthand for Power
Supply Unit.
PS51 Outputs
will be on the display. Press YES or scroll to power supply numbers and then press YES.
You should see
O1 Unused -
on the display. Press YES or scroll to other individual output numbers on the
unit in question and then press YES. You can now select an output type from the list on page 75.
Once you have selected your output type you will be prompted to select between negative or positive polarity.
2
Devices Menu
2
Devices Menu
7
Outputs Menu
2
Add & Id: PS51.55
2
Locate : PS51.55
2
Wired Devices Menu
2
Wired Devices Menu
1
RF Devices Menu
1
RF Devices Menu
1
Add & ID Devices
1
Add & ID Devices
PS51 Outputs
O1 Unused -
PS52 Outputs
O2 Unused -
PS53 Outputs
1
Add & ID: Keypads
1
Locate : Keypads
2
Add & ID: Z5 Devices
2
Locate : Z5 Devices
3
Add & ID: Z6 Devices
3
Locate : Z6 Devices
4
Add & ID: Z7 Devices
4
Locate : Z7 Devices
5
Add & ID: Z8 Devices
5
Locate : Z8 Devices
6
Add & ID: Expanders
6
Locate : Expanders
2
Locate Devices
2
Locate Devices
3
Remove Devices
3
Remove Devices
1
Service Menu
1
Service Menu
6
Timers Menu
1
Add & Id: P50..P59
1
Locate : P50..P59
3
Zone Menu
3
Zone Menu
8
System Options
3
Add & Id: OC51.55
3
Locate : OC51.55
Mains Fault
Battery OK
Fault
Battery Test
1 Amp total
2 Amp total
12V POWER SUPPLY
3
PSU Outputs
1
Panel Outputs
2
Expander Outputs
4
Output Card Outputs
5
Output Groups