2.3 Basic Connection Structure
The picture below is an example of basic connection structure. This controller needs to
be supplied with single-phase AC200-240V, and the ground connection should be
separated from main power breaker. Do not connect the ground by devices or system
ground, the best way is to connect to power ground directly, and high-quality wires
which diameters are 14AWG or more should be used. The power can be turned on and
tested after connecting the main components mentioned below.
No.
Item
1
CN1 Main Power Cable
2
CN2 Motor Signal Cable
3
CN3 Emergency Stop Switch
4
CN4 Teach Pendant