![Hiwin RC4 Original Instruction Download Page 54](http://html1.mh-extra.com/html/hiwin/rc4/rc4_original-instruction_2140486054.webp)
C21UE102-2110
52
table below is four different condition states.
CH A
CH B
Controller State
CLOSE
CLOSE
Normal
OPEN
OPEN
emergency stop on
OPEN
CLOSE
emergency stop on
and safety circuit abnormal *
CLOSE
OPEN
emergency stop on
and safety circuit abnormal *
*When safety circuit abnormal , please to cut off both double-loop, after enter emergency stop on state ,
clear error alarm and returned.
The emergency stop device must be connected to the controller and be placed at the position
accessible to the
operator, and any signal or power source should not come into contact with any
metal enclosure. Incorrect method of using can cause a severe damage or loss of life and property.