1-61
TROUBLESHOOTING
Cause
Check Item
Action
(Turn OFF Main Switch)
Phenomenon
Check continuity
during stoppage.
Faulty CT
Replace CT when faulty.
Fault
Measure resistance
by tester.
Remove looseness
and replace connector.
Incorrect
Connection
Check wiring.
Correctly wiring.
Incorrect
Wiring
Imbalance Among
Phase at Power Source
Excessively High or
Low Voltage of
Power Source
Excessively Large
Running Current of
Compressor Motor
Adjust voltage between
each phase.
Excessively High
Discharge Pressure
Operate within
380-415V 10% (50Hz)
380V 10% (60Hz)
220V 10% (60Hz)
+
−
+
−
+
−
Check for causes.
Overcurrent
of Compressor
Motor
Locked-up?
Replace compressor.
Seizure of Compressor
Bearing
Looseness of Screws
for Power Source
Single Phase Operation
Tightly fix screws.
Deterioration of Contact
of Magnetic Switch for
Compressor
Replace magnetic
contactor.
Measure insulation
resistance.
Replace compressor.
Insulation Failure of
Compressor Motor
Melted Fuse for
Power Source
Replace the fuses.