2-91
SERVICING
(2.6 Wall Type)
Phillips Screwdriver
Tool
TURN OFF all power source switches.
(5) Draw the fan leftward with lifting up the bearing side of the fan slightly, the fan and the fan motor are
removed.
Phillips Screwdriver
Tool
(6) For attaching the fan motor and the fan, perform the reverse procedures for removing.
(7) Fix the fan at the position with 8mm clearance between the left end (bearing side) of the fan and the
partition plate.
(8) Fix the fan motor with the outlet of the lead wire at the position as shown below.
Loosen Screw
Fan Motor
Lift up the fan and draw it leftward.
60
o
Lead Wire of Motor
Fan Motor
Partition Plate
Bearing
Fan
8mm
Fan Motor