5. CONTROLLING THE HARDWARE
5-9
<Diagnosis>
When the raidctrl command finishes normally, it returns exit code 0.
If the command returns abnormally, one of the error messages listed in Table 5-3 is
displayed, and the command returns an exit code other than 0. As an exception, if message
number 4 or 5 is displayed, the command returns exit code 0.
Table 5-3 Error Messages of the raidctrl Command
No.
Error message
Description
1
Usage:raidctrl [/OFFLINE HDDNO]
[/NOTIFY [{ON|OFF}]]
There is an error in the specified options.
Specify correct options.
2
Invalid argument. (%1)
Specified option %1 is not correct.
3
Specified HDD is not valid.
The specified drive is not connected or is in the unknown state.
4
Specified HDD is already OFFLINE.
The specified drive is already disconnected.
5
Specified HDD is the only ONLINE drive.
The specified drive is the only drive that operates normally.
6
Specified HDD is rebuilding.
The specified drive is under the rebuild process.
7
An error occurred in %1. errorcode = %2
An unexpected error (%2) occurred in the function (%1). Retry
the command. If the same error message persists, restart this
equipment.
8
You do not have the privilege to execute this
command option.
Please execute this command option again on
“Administrator: Command Prompt”.
You do not have administrator privileges.
Log on to the computer using an administrator account and run
the command again. If User Account Control (UAC) is enabled,
start the command prompt with administrator privileges and run
the command.
9
Access denied.
Log on console session,
And execute this command option again on
“Administrator: Command Prompt”.
You cannot use this command with this option from a remote
session.
Log on to a console session and run the command again. If User
Account Control (UAC) is enabled, start the command prompt
with administrator privileges and run the command.
10 raidctrl: This function was executed on a
non-RAID model.
The command is executed on a model other than D Model.
This command can be executed on D Model only.
Summary of Contents for HF-W6500 45/40
Page 1: ...WIN 63 0088 02 ...
Page 2: ...WIN 63 0088 02 ...
Page 21: ...This page is intentionally left blank ...
Page 35: ...This page is intentionally left blank ...
Page 79: ...4 CHECKING THE HARDWARE STATUS 4 26 5 In the SNMP Service Properties window click Apply ...
Page 91: ...This page is intentionally left blank ...
Page 105: ...This page is intentionally left blank ...
Page 137: ...This page is intentionally left blank ...