5.3 FL.NET Module Setup Procedures
5.3.1 Startup
procedure
The startup procedure for the FL.NET module is described below:
①
Switch OFF the CPU unit or LPU unit and then install the FL.NET
module.
②
Set the module number selector switch on the FL.NET module, as
indicated below:
MODU No.
Main Sub
Description
0 1
10BASE5
communication
2 3
10BASE-T
communication
③
Swicth ON the CPU unit or LPU unit.
④
Connect the CPU unit or LPU unit to the Windows® personal computer
via an RS-232C interface cable or Ethernet. Start the setup tool named
“FL.NET For Windows®” (See “5.5 Installing and Starting up the
System.”).
⑤
Set the IP address and subnet mask for the FL.NET module. (For IP
address and subnet mask setup procedures, see item (1), “IP
address/subnet setup precautions,” on the next page.)
⑥
Reset the CPU unit or LPU unit.
⑦
Set up the FL.NET module.
Start
Mount the module.
Set rotary switch.
Start up CPU or LPU.
Windows®
PC programming
(FL.NET For Windows®)
Reset CPU or LPU.
Set up the FL.NET module.
End
Set the FL.NET
module IP address.