5 USER GUIDE
5-50
To set up the FA link status/higher layer flag area, use the setup window for the other nodes
reception setup.
Enter the FA link and higher layer status settings.
Make an entry
specifying the higher
layer status transfer
area for each node.
Make an entry
specifying the FA link
status transfer area
for each node.
Shows the self-node number area setup.
Figure 5-44 Setup Window for Setting the Status Flag Areas for the
Other Nodes Reception Setup
The table below shows the acceptable input ranges for the input items.
Input item
Description
Acceptable input range
FA link status
Specify the area to which the FA link
status of the node having the node
number indicated at the left end is to be
transferred (the area size is 1 word).
See Table 5-7, “Address Ranges for
Common Memory Area Allocation in CPU
or LPU Memory.”
Higher layer status
Specify the area to which the higher
layer status of the node having the node
number indicated at the left end is to be
transferred (the area size is 1 word).
See Table 5-7, “Address Ranges for
Common Memory Area Allocation in CPU
or LPU Memory.”
For the on-screen information (bit allocation) concerning the FA link status and higher layer
status, see “5.4.6 Using the management tables.”
Summary of Contents for FL.NET
Page 1: ......
Page 2: ......
Page 29: ...1 OVERVIEW ...
Page 33: ...2 FL NET MODULE ...
Page 42: ...3 FL NET MODULE INSTALLATION ...
Page 46: ...4 FL NET MODULE WIRING PROCEDURES ...
Page 53: ...5 USER GUIDE ...
Page 203: ...5 USER GUIDE 5 151 Sample printout ...
Page 206: ...6 MAINTENANCE ...
Page 210: ...7 TROUBLESHOOTING ...
Page 225: ...8 APPENDIXES ...