8.3 Selecting the Connections and Protocol
106
To be checked before setting
The settings are different when the device and external device are connected to
the existing network and when the device and a PC are connected to a new net
-
work.
Connecting the device to the existing network
The network administrator (department) needs to assign the following items in
advance. Be sure to
assign them so that they do not overlap with other devices.
Creating a new network using the device and a PC
(Using a local network that is not connected externally)
The addresses shown below are recommended if there is no administrator or
you are responsible
for setting.
Setting LAN communications
• Address settings of the device
IP address:
................................................................................................
___.___.___.___
Subnet mask:..................................................___.___.___.___
• Gateway
Whether or not to use a gateway:...................Use / Not use
IP address (if used):........................................___.___.___.___
........................................................................(Set to 0.0.0.0 if not used)
Communication command port No. to be used:____(Default setting: 23)
IP address
Set sequential IP addresses as shown below.
PC:...........................................................192.168.1.100
First device:..............................................192.168.1.1
Second device: .......................................192.168.1.2
Third device: ............................................192.168.1.3
.................................................................↓
Subnet mask:...........................................255.255.0.0
Gateway:..................................................OFF
Communication command port number: .23
1
Start a web browser.
You can change the instrument's LAN interface settings using a web browser, such
as Microsoft Edge
®
.
The description below uses Microsoft Edge
®
as an example.
(1) Click the start button on the bottom-left corner of the computer screen, and then
click
[Microsoft Edge]
in the menu.
(2) Enter the character string
[http://]
followed by the IP address or the computer
name in the address bar
When the IP address of the instrument is “192.168.1.1”
HIOKI BT3562A981-09
Summary of Contents for BT3562
Page 2: ...HIOKI BT3562A981 09...
Page 24: ...1 5 Measurement Flowchart 18 HIOKI BT3562A981 09...
Page 84: ...4 13 Reset Function 78 HIOKI BT3562A981 09...
Page 102: ...6 3 Printing 96 HIOKI BT3562A981 09...
Page 186: ...8 8 Sample Programs 180 HIOKI BT3562A981 09...
Page 198: ...10 3 Error Display 192 HIOKI BT3562A981 09...
Page 200: ...194 HIOKI BT3562A981 09...
Page 220: ...Appendix 11 Dimensional Diagram A20 HIOKI BT3562A981 09...
Page 224: ...Index HIOKI BT3562A981 09...
Page 225: ...HIOKI BT3562A981 09...
Page 226: ...HIOKI BT3562A981 09...
Page 227: ...HIOKI BT3562A981 09...
Page 228: ...HIOKI BT3562A981 09...