34
―――――――――――――――――――――――――――
Chapter 2
Measurement Procedure
――――――――――――――――――――――――
MAX/MIN
display
Elapsed time
display
Remaining
battery
capacity display
NOTE
Items Displayed (Marked OK) and Not Displayed (-)
1
φ
P
1
φ
PF
3
φ
PF
Current I
OK
OK
OK
Current peak value
Ipeak
OK
OK
OK
Voltage U
OK
OK
OK
Voltage peak value
Upeak
OK
OK
OK
Effective power P
OK
-
OK
Apparent power S
OK
-
OK
3. Pressing the
MODE
key while using the recording
function lets you check the elapsed time and
remaining battery capacity.
In elapsed time display, the instrument indicates
hours on Display 2 and minutes on Display 3.
When elapsed time is displayed with MAX or MIN
blinking, a negative value is denoted.
4. The
HOLD
key will suspend the recording
function.
HOLD
annunciator lights and
REC
annunciator stops blinking.
While
HOLD
is shown, the elapsed time is not
increasing. By pressing the
HOLD
key once more,
HOLD
annunciator is off and the recording function
resumes.
5. To reset the recording data during the recording
function, press the
MAX/MIN
key.
When starting the recording function (
REC
) in an
auto range, the range is set as the recording
function is activated.