45
―――――――――――――――――――――――――――
Chapter 3
Specifications
――――――――――――――――――――――――
Measurement
accuracy
Harmonic levels
Order
Accuracy
1
3.0%rdg.
10dgt.
2 to 6
3.5%rdg.
10dgt.
7 to 8
4.5%rdg.
10dgt.
9 to 10
5.0%rdg.
10dgt.
11 to 15
7.0%rdg.
10dgt.
16 to 20
10%rdg.
10dgt.
Harmonic
percentage
Total harmonic
distortion ratio
1 dgt. with respect to calculation from
each measured value.
1 dgt. with respect to calculation from
each measured value.
Operating system
Digital sampling system
Phase detection system
Single-phase Power
Measurement
Power Factor & Phase
Angle Measurement
Waveform
Digital sampling
-
Phase
-
Phase detection
Three-phase Power
Measurement
Harmonic Measurement
Function
Waveform
Digital sampling
Digital sampling
Phase
Phase detection
-
Accessory Functions:
Phase detection (at 3-
phase balanced load)
Normal/ Reverse/ Missing
(50/60 Hz, sine wave)
Recording
Maximum (MAX) and minimum (MIN)
values display selectable for current,
voltage, and effective / apparent power
measurements
Data hold
Data hold function
3.2 General Specifications
Summary of Contents for 3286-20
Page 17: ...xiv Organization of This Manual...
Page 29: ...12 Chapter 1 Product Outline...
Page 55: ...38 Chapter 2 Measurement Procedure...
Page 69: ...52 Chapter 3 Specifications...
Page 73: ...56 Chapter 5 Attaching The Hand Strap...