24
―――――――――――――――――――――――――――
Chapter 2
Measurement Procedure
――――――――――――――――――――――――
1 (R)
2
(S)
3
(T)
1
φ
P, P
1
1
φ
P, P
2
P
o
w
e
r
s
u
ppl
y
side
Lo
ad
Red
Yellow Black
Red
Black
Yellow
Three-phase effective power P=P
1
+P
2
Measurement example
P (1
φ
P)
S (1
φ
P)
R
-0.54 kW
2.61 kVA
T
1.98 kW
2.57 kVA
Three-phase effective power
P=P1+P2=-0.54+1.98=1.44 kW
Three-phase apparent power
S=( )/2 (2.61+2.57)=4.49 kVA
Power factor
λ
=P/S=1.44/4.49=0.321
Summary of Contents for 3286-20
Page 17: ...xiv Organization of This Manual...
Page 29: ...12 Chapter 1 Product Outline...
Page 55: ...38 Chapter 2 Measurement Procedure...
Page 69: ...52 Chapter 3 Specifications...
Page 73: ...56 Chapter 5 Attaching The Hand Strap...