47
―――――――――――――――――――――――――――
Chapter 3
Specifications
――――――――――――――――――――――――
Zero suppression
5 counts (for current and voltage
measurement)
Location for use
Indoor, altitude up to 2000 m (6562 feet)
Applicable standards
Safety:
EN 61010
Measurement categories III (expected
transient overvoltage: 6000 V), Pollution
level 2,
EN 60529 IP40 (protected against access
to hazardous parts with a wire)
EMC:
EN 61326
Maximum conductor
diameter for
measurement
φ
55 mm max.
80 x 20 mm bus bar
Operating temperature
and humidity range
0 to 40
(32 to 104
),
80%RH or less (no condensation)
Temperature
characteristics
Current and voltage
measurement
In 0 to 40
range: 0.1 x accuracy
specifications/
Phase detection
circuit
In 0 to 40
range: Within
2 deg.
Storage temperature
range
-10 to 50
(14 to 122
, no condensation)
Power source
6LR61, 6LF22 alkaline battery
9V x 1
Maximum power
consumption
220 mVA
Battery life
Alkaline battery (6LR61, 6LF22)
approx. 25 hours
Manganese battery (6F22) approx. 10 hours
External dimensions
Approx. 100W x 287H x 39D mm
Approx. 3.94"W x 11.30"H x 1.54"D
Mass
Approx. 650 g (except for the battery)
Approx. 22.9 oz. (except for the battery)