Control Panel
59/258
8.5.3
Field
Open this page with
Network > Field
.
In order to access this page you require the following access right:
Access to Field
On this page you configure the operating mode of the fieldbus interface
(Real-Time Ethernet). The fieldbus interface is deactivated when delivered
(factory setting).
Operating mode Description
Active
In the operating mode
Active
, the device can send and receive data on
the fieldbus interface.
Note:
The operating mode
Active
is required for
the typical operation of the Edge Gateway.
In this operating mode, select a firmware: PROFINET IO Device or
EtherNet/IP Adapter.
Note:
Do not use the PROFIBUS DP Slave
firmware.
In Node-RED use
·
the fieldbus input node to receive data from the fieldbus (see section
Example 6: Fieldbus input node
·
the fieldbus output node to send data to the fieldbus (see section
Example 7: Fieldbus output node
Inactive
The interface is deactivated.
Table 24: Operating mode fieldbus interface
Edge Gateway | NIOT-E-TPI51-EN-RE (Connect)
DOC170502UM04EN | Revision 4 | English | 2018-08 | Released | Public
© Hilscher 2017 – 2018