Node-RED - The wiring editor
111/258
If you select
Add new opcua client
in the list
Server
and click Edit
thereafter, the dialog box
Add new opcua-client config node
will be
displayed. In this dialog box you can configure a parameter for a
connection to an OPC UA server.
Figure 86: Dialog box „Add new opcua client config node“
The address of the OPC UA server is structured as follows:
opc.tcp://
<IP address>:port
Example:
opc.tcp://192.168.253.12:4840
Port 4840 is the standard port for unencrypted OPC UA communication.
Tab
Browse
Figure 87: Dialog box Edit OPC UA out node – tab Browse
The left window of the tab
Browse
displays the objects in a tree structure.
The right window displays the attributes of the object selected in the left
window. To be able to use the browser function, you must have entered the
OPC UA server address, transmitted the OPC UA output node to the Edge
Gateway by means of Deploy, and established a connection to the OPC UA
server.
Edge Gateway | NIOT-E-TPI51-EN-RE (Connect)
DOC170502UM04EN | Revision 4 | English | 2018-08 | Released | Public
© Hilscher 2017 – 2018