Control Panel
40/258
Setting the system time manually
Ø
Click the option
Manual
.
Ø
Enter the time in the input field
Time
in the format
hh:mm:ss
.
Ø
Set the date using the calendar input field
Date
.
Ø
Click
Save changes
.
Ø
Reboot the device:
System
>
Reboot
in order that all software
components in the Edge Gateway take the changed time.
ð
The system time is set.
Setting the system time automatically using a time server
You can synchronize the time using a time server that uses the Network
Time Protocol (NTP). Under
NTP synchronized
there is a list where you
can enter such time servers. The list of NTP servers will be worked off from
top to bottom until a server gives a valid answer and synchronization
occurs.
Ø
Click the option
NTP Synchronized
.
Ø
Click
Add NTP server
.
Ê
The dialog box for entering the NTP server is displayed.
Ø
In the input field
NTP server
enter the address of a server which uses
the NTP to synchronize the time:
E.g.: To add the server for time synchronization of the Physikalisch-
Technische Bundesanstalt (the National Metrology Institute of
Germany) to the list, enter the address
ptbtime1.ptb.de
in the input
field
NTP server
.
Ø
Click
Add
.
Ø
Click
Save changes
.
Ø
Reboot the device:
System
>
Reboot
in order that all software
components in the Edge Gateway take the changed time.
ð
The system time is set via the NTP. As soon as the system time is set
successfully, the following information will be displayed under
Status
:
Synchronized to time server <IP address of the time
server>:<Port number of the time server > (<NTP
address of the time server>)
Edge Gateway | NIOT-E-TPI51-EN-RE (Connect)
DOC170502UM04EN | Revision 4 | English | 2018-08 | Released | Public