Examples for Node-RED
127/258
8. Inserting the Debug node:
Ø
Drag a
Debug
node from the node library and drop it in the worksheet.
9. Connecting the nodes:
Ø
To connect the
OPC UA
node with the
Debug
node, hold down the left
mouse button and draw a connecting line (wire) from the output port of
the OPC UA node to the input port of the Debug node.
10. Deploy:
Ø
Click
Deploy
to transmit the nodes, that have so far existed in the editor
only, to the device and activate them.
ð
The flow is activated in the Edge Gateway.
The section
page 104] describes the parameters of
the OPC UA input node.
Testing the flow and displaying messages
Ø
Click the tab
Debug
in the sidebar.
ð
If the OPC UA input node has a connection to the OPC UA server, the
Debug node displays every 10 seconds messages of the OPC UA node
which contains the value of the object read.
Edge Gateway | NIOT-E-TPI51-EN-RE (Connect)
DOC170502UM04EN | Revision 4 | English | 2018-08 | Released | Public
© Hilscher 2017 – 2018