GWY-500

(Profibus Gateway)

USER’S MANUAL

Summary of Contents for GWY-500

Page 1: ...GWY 500 Profibus Gateway USER S MANUAL ...

Page 2: ...ill at its option repair or replace the Product returned to it freight prepaid which fail to comply with the foregoing warranty provided Renu Electronics Pvt Ltd is notified of such noncompliance within the one year warranty period ASSISTANCE This manual is designed to provide the necessary information for trouble free installation and operation of your new Gateway product However if you need assi...

Page 3: ...ld be performed on a unit substitution basis only Do not attempt to remove replace or service any printed circuit board components or any hardware software related with display product If problem within the display product occurs contact the factory for service information or repair NOTE Renu Electronics Pvt Ltd is dedicated to providing complete customer service and customer satisfaction If you h...

Page 4: ...ownload 19 3 4 1 When GWY 500 can accept configuration 20 GWY 500 B FEATURES 21 4 1 Gateway Modes 22 4 1 1 Master Master Configuration 22 4 1 2 Master Slave Configuration 25 4 2 Repeat Cycle 28 4 3 Control Word 28 4 4 Error Indication Bit 29 4 5 Communication Parameters 29 4 6 Default Communication Register 30 4 7 Recipes 31 4 8 Control word for IDB 32 4 9 Diagnostic 33 4 10 Profibus Connection St...

Page 5: ... 500 PROFIBUS PORT 82 10 1 4 SIEMENS MASTER PROFIBUS PORT TO GWY 500 PROFIBUS PORT 83 10 1 5 NS TO GWY 500 84 10 1 6 THOMSON TECHNOLOGY CONTROLLER TO GWY 500 85 10 1 7 OPTOMUX TO GWY 500 86 10 1 8 YOKOGAWA CONTROLLER TO GWY 500 87 10 1 10 AB MICROLOGIX SERIES PLCs TO GWY 500 EC P 027A 00 88 10 1 9 AB SLC DH485 PORT TO GWY 500 EC P 007 00 89 10 1 12 OMRON CQM1 PLC TO GWY 500 EC P 006B 00 90 10 1 11...

Page 6: ...Introduction 1 Doc No UMAN GWY 500 B 0106 REVISION 4 INTRODUCTION In this chapter Purpose of this manual Introduction To Gateway GWY 500 B Specifications ...

Page 7: ... this publication without prior notice 1 2 Introduction to Gateway Gateway is a Protocol Converter Data sharer for devices like PLCs inverters Adjustable Speed Drives and other Control lers Gateway has two serial ports that connect with two different devices These devices share data through Gateway Gateway communicates with a device to get the information required by the device connected on the ot...

Page 8: ... via Profibus port and serial device PLC or Inverter via the PLC s communi cations port correct cables are required and the PLCs can easily exchange information with the Profibus DP devices PLC1 Profibus DP Protocol PLC Profibus Master PLC Drive Motor Node n PID Controller Node 1 X Protocol GWY 500 B Node 2 PLC ...

Page 9: ...t 125 gm approx Certifications CE with UL certification Immunity to ESD Level 3 as per IEC1000 4 2 Immunity to Transients Level 3 as per IEC1000 4 4 Immunity to Radiated RF Level 3 as per IEC1000 4 3 Immunity to Conducted RF Level 3 as per IEC1000 4 6 Emissions EN55011 CISPRA Note1 If Toshiba VF S11 Inverter is connected at COM1 of GWY 500 station number is detected automatically at power ON and t...

Page 10: ...Hardware 5 Doc No UMAN GWY 500 B 0106 REVISION 4 HARDWARE In this chapter Dimensional Details And Mounting Instructions Communication Port Details LED Status ...

Page 11: ...il plate also has the provision to screw the unit to the back panel Following drawing shows how to attach the DIN rail plate to the unit Follow instructions given below 1 Attach the DIN rail plate to the unit using the clamps on the DIN rail plate 2 Pull out the clip of the plate 3 Put the unit on the DIN rail 4 Push the clip in to secure the unit on the DIN rail GWY 500 unit is shipped with a sep...

Page 12: ...32 RS422 RS485 and CMOS signal levels Pinout of this port is given as follows TX RS422 RS485 DB9 Female 1 5 9 6 5VDC DO NOT USE Signal Ground RX RS422 RS485 RXD RS232C CMOS TXD RS232C TX RS422 RS485 TXD CMOS RX RS422 RS485 6 8 9 7 2 4 5 3 1 PLC1 COM1 Do not use pin no 6 of PLC1 COM1 Refer our website www renuelectronics com for your specific Cable requirements ...

Page 13: ...XB 9 RX RS422 RS485 Differential Receive also referred as RXB Pin Description User can convert RS485 4 wire Signal Ground system to a 2 Wire Signal Ground system by shorting following signals in the communication cable TX TX A RX B RX SG SG Note If user has attached shield to Earth on Device end leave the shield open on Gateway end If user has connected shield to Signal Ground on Device end connec...

Page 14: ...round is meant for the direction control of repeaters in case repeaters without self control capability are used 5V DC Data Ground The signals 5V DC and Data Ground are meant to power an externally mounted bus terminator The powering of the 220 termination resistor ensures a defined idle state potential on the data lines To ensure proper functioning up to the highest baud rate each bus segment has...

Page 15: ...F Configuration Ok ON Configuration Fault PLC1 Green OFF No data received on PLC1 Port Flashing Receiving data on PLC1 Port ON Red OFF No error in PLC1 attach or while block execution Flashing PLC1 attach error or error while block execution ON Profibus Green OFF No data received on Profibus Port Flashing Receiving data on Profibus Port ON Red OFF Data exchange with Profibus Master Flashing ON No ...

Page 16: ...sts to serial ports device This process is continued until a device connected on serial port is detected If that device is detected Profibus port is initialised After successful Profibus initialisation gateway 500 starts exectuting the project blocks At this point Ok LED is steady ON serial port and Profibus LED are blinking Now if the gateway 500 detects that Profibus master is not present then i...

Page 17: ...Getting Started 12 Doc No UMAN GWY 500 B 0106 REVISION 4 GETTING STARTED In this chapter Introduction To Profibus Introduction To GWY 500 B GWY 500 B Operation ...

Page 18: ...olution for communication tasks at a higher level Powerful services open up a wide range of applications and provide great flexibility It can also be used for extensive and complex communications tasks Uniform bus access PROFIBUS DP and PROFIBUS FMS use the same transmission technology and a uniform bus protocol access protocol Thus both versions can be operated simultaneously on the same cable Ho...

Page 19: ... s can be selected One unique transmission speed is selected for all devices on the bus when the system is commissioned Cable length The maximum cable length depends on the transmission speed The specified cable lengths are based on type A cable The length can be increased by the use of repeaters The use of more than 3 repeaters in series is not recommended 3 1 2 Device Types PROFIBUS distinguishe...

Page 20: ...master executes this procedure automatically A user can only change the target rotation time but is not recommended Polling procedure The polling or master slave procedure permits the master which currently owns the token to access its assigned slaves The picture below shows a possible configuration The configuration shows three active stations masters and six passive stations slaves The three mas...

Page 21: ...tage Module related 2 Module related diagnostics diagnostics These messages indicate that a fault is present in a specific I O range e g an 8 bit output module of a station Channel related 3 Channel related diagnostics These messages indicate an error at an individual input or output e g short circuit on output 5 3 1 3 4 Protection Mechanism Time monitoring PROFIBUS DP provides effective protectio...

Page 22: ...d DP slaves The data exchange comprises reading the inputs of the DP slaves and writing zero s to the outputs of the DP slaves Operate 4 Operate DPM1 master exchanges data with its assigned slaves inputs are read and outputs are written Beside this the DPM1 cyclically sends its local status to all assigned DP slaves with a multicast message at a configurable time interval Auto_Clear When an error ...

Page 23: ...usage of the GSD file in the master s configuration software GSD files are usually supplied with each unit Alternatively GSD files can be downloaded from the Internet either from the manufacturer s site or from the GSD library of the PROFIBUS Nutzerorganisation at http www profibus com 3 1 5 Profiles Exchanging devices To enable the exchange of devices from different vendors the user data has to h...

Page 24: ...can now communicate with the Profibus DP Slave devices and serial devices e g PLC or SCADA 3 3 GWY 500 Configuration GWY 500 can communicate with serial and Profibus devices using appropriate cables and configuration Microsoft Windows based configuration software Gateway Setup configures the GWY 500 unit Configuration means making the GWY 500 unit work as per system requirements Complete configura...

Page 25: ...o serial port of converter 3 4 1 When GWY 500 can accept configuration If current driver present for PLC1 port is Master e g Modbus Gateway as Master First it is checked that whether device is connected on port1 If device is connected it continues normal operation If device is not connected it checks for IBM download mode for 10sec This sequence continues until either is satisfied If current drive...

Page 26: ...0106 REVISION 4 21 GWY 500 B FEATURES In this chapter Gateway Modes Repeat Cycle Control Word Error Indication Bits Communication Parameters Default Communication Register Recipes Control word for IDB Diagnostic Profibus Connection Status word ...

Page 27: ...e both Gateway ports are master in nature and devices connected on these ports are slave Gateway ports initiate communication when the proper Gateway Device communication cable is attached Data is transferred in blocks This transfer can either be a continuous process or as per requirement A control word Section 4 3 present in device on either side enabled from Gateway Setup Software can control th...

Page 28: ... Gateway project it is possible for serial devices to read the data from Output Area and also they can write the data in Input Area This memory is shared memory for Profibus master devices and Gateway firmware system as shown bellow Gateway Firmware System Any Serial Driver COM2 Profibus slave driver COM1 100 words Input 100 words Output 3K Internal Database Memory Gateway firmware system and exte...

Page 29: ...en between two devices Block 1 Gateway reads 16 words starting from 400001 from Modbus and write these 16 words data to internal memory of Profibus Input area Block 2 Gateway reads 16 words starting from O000 in internal memory of Profibus Output area and writes it to holding register starting from 400020 As this example has only two blocks Gateway will execute Block 1 after executing Block 2 cont...

Page 30: ...ea so in this mode any Block is used for mapping registers of the two devices In Block Definition area Words Field indicates number of registers to be mapped linearly from the starting addresses of the Source Device to the Destination Device Maximum number of registers that can be mapped is 255 but this does not mean that Master Device has to read write 255 registers in one command In one command ...

Page 31: ...GWY 500 B Features Doc No UMAN GWY 500 B 0106 REVISION 4 26 ...

Page 32: ...Block 2 Gateway accepts this command and sets I000 If Master sends a command to read write a register coil not defined in any Block then Gateway sends exception response to master NOTES 1 If multiple registers are to be read or written in one command then all the registers have to be de fined in one Block 2 As Gateway Setup Software is common for both the Gateway Modes titles in the Block Definiti...

Page 33: ...lock 4 Cycle 2 Block 1 Cycle 3 Block 1 Block 2 Cycle 4 Block 1 Block 3 Cycle 5 Block 1 Block 2 Block 4 4 3 Control Word Another way of controlling Block execution is by use of the Control Words 16 control words i e 255 control bits are available by which user can control 255 blocks Oth Control bit corresponds Oth bit of control word 1 16st Control bit corresponds 0st bit of control word 2 255th Co...

Page 34: ...e designated in each external device connected to Gateway Using this bit fault at the PLC1 end can be reported to PLC2 Device and fault at PLC2 end can be reported to PLC1 Device When communication error occurs on PLC1 Gateway sets error bit in PLC2 device Error Indication Bit can only be used in Master Master mode In Master Slave mode any error can easily be detected by a communication time out o...

Page 35: ...or attach But if a particular device does not respond to 400001 then the initialization will fail What does the Default Communication Register do After power up default communication register is the first register that is fetched by the master driver from the slave device If response for this register is received from slave then only gateway will start the Profibus initialization Otherwise GWY 500...

Page 36: ...se of some Slaves it is necessary to write configuration properties or control sequences at power on Drives Inverters generally require this kind of sequence After power on before Gateway Project Block execution starts Recipes blocks will be executed and the specified value will be written into the specified registers NOTE 1 Recipes are only useful for master drivers 2 All the fields in Recepies i...

Page 37: ...so all IDB block will execute After communication is totally established user can change internal memory data to execute required IDB block Why when is the Control Word for IDB required S1 M1 S2 M2 Let us assume the User has defined different Blocks in the Project in Master Slave Mode that gives rise to 20 blocks in IDB of M1 as this is a Master Driver Now if the external Master M2 requires execut...

Page 38: ... GWY 500 is showed in configured Profibus Diagnostic Input Word State Description 1 Scanning nodes on serial side 2 IBM Download mode 3 Reserved 4 Data Exchange 4 10 Profibus Connection Status word This indicates Profibus status on serial side One internal memory register is added in Profibus Driver IM0000 Its read only word User can map this register while configuring the project Data in IM0000 D...

Page 39: ...Note on Communication Drivers Doc No UMAN GWY 500 B 0106 REVISION 4 34 NOTE ON COMMUNICATION DRIVERS ...

Page 40: ...Input 100 words Output 3K Internal Database Memory Gateway firmware system and external profibus master both act as a master on this memory Though Gateway Profibus driver is slave with respect to external profibus master device Gateway firmware system assumes this driver as a master driver as it is master to 200 words internal memory Note Profibus detects baud rate automatically So baud rate field...

Page 41: ...Note on Communication Drivers Doc No UMAN GWY 500 B 0106 REVISION 4 36 Let us have a glance at Internal database Please refer the following example ...

Page 42: ...So time required for read cycle is optimized 2 Write operations are on comparison basis Since all the registers data is already present in internal database memory of Gateway driver every time before performing write operation data is compared with the internal memory data In this way unnecessary write operations can be avoided The PLC2 driver uses this data whenever needed according to gateway pr...

Page 43: ...e master driver will read all the data and load it into the internal database memory But in case of write operation each master driver will check the data available in the internal memory with the new data to be written If the data in the internal memory is same as the new data then Gateway software will skip the write command In case of different data master driver will initiate the write command...

Page 44: ...ON 4 TYPICAL PROJECTS In this chapter Project Setup Connect Toshiba Inverter as Profibus DPV0 Slave on Profibus Network with GWY 500 B Connect Modicon PLC as Profibus DPV0 Slave on Profibus Network with GWY 500 B Connect SCADA Software on Profibus Network ...

Page 45: ...rotocol of Device s connected to PLC2 2 Load Microsoft Windows based Gateway Setup software 3 Select devices to be connected on two ports 4 Define Blocks for data transfer 5 Set the communication parameters for the selected devices 6 Set conditions for block execution if required Repeat Cycle Control Word etc 7 Apply power to Gateway 8 Download the Project and Communication Drivers into Gateway 9 ...

Page 46: ...r as Profibus DPV0 Slave on Profibus Network with GWY 500 This project reads the parameters of Inverter connected on COM1 and writes the parameters to PLC Controller con nected on COM2 and vice versa COM1 Protocol Toshiba S11 COM2 Protocol Profibus Both thses Protocols does not need IDB ...

Page 47: ...updated in I003 Block 5 The output voltage of the inverter is read and updated in I004 Block 6 The current of the inverter is read and updated in I005 Block 7 The error history code of the inverter is read and updated in I006 Block 8 The value of O000 is set as command frequency of the inverter Block 9 According to the value of O001 the inverter is Run Stop Block 10 The value of O002 is set as Acc...

Page 48: ...s 43 Doc No UMAN GWY 500 B 0106 REVISION 4 6 3 Connect Modicon PLC or other Modbus Slave devices as Profibus DPV0 Slave on Profibus Network with GWY 500 B COM1 Protocol Modbus Master COM2 Protocol Profibus DPV0 Slave ...

Page 49: ...s as follows Block 1 Gateway reads 16 words starting from 400001 from Modbus and write these 16 words data to internal memory of Profibus Input area Block 2 Gateway reads 16 words starting from O000 in internal memory of Profibus Output area and writes it to holding register starting from 400020 ...

Page 50: ...Typical Projects 45 Doc No UMAN GWY 500 B 0106 REVISION 4 6 4 Connect SCADA Software on Profibus Network COM1 Protocol Modbus Slave COM2 Protocol Profibus DPV0 Slave ...

Page 51: ...Slave on Profibus Network Block 1 maps 100 words of Modbus starting from 300001 to Profibus starting from O000 Block 2 maps 100 words of Modbus starting from 400001 to Profibus starting from I000 Note I000 is the first word of Input Area in Internal Memory of Profibus driver O000 is the first word of Output Area in Internal Memory of Profibus driver ...

Page 52: ...Configuration Software Doc No UMAN GWY 500 B 0106 REVISION 4 47 CONFIGURATION SOFTWARE In this chapter System Requirements Installation Instruction ...

Page 53: ...ted and stored in a safe place 1 Launch the Windows operating system 2 Insert the setup CD into CD drive 3 Point to the start button then click RUN 4 In the command line box enter E Disk1 setup exe Click OK This will launch the Gateway installer 5 Follow the instructions to complete setup Gateway Project Each Gateway must be configured before connecting it to the PLC Gateway configuration software...

Page 54: ...Creating Project 49 Doc No UMAN GWY 500 B 0106 REVISION 4 PROFIBUS MASTER SETUP In this chapter Setup of GWY 500 B withOmron Profibus master Setup of GWY 500 B withSiemens Profibus master ...

Page 55: ...ON 4 8 1 Setup Of GWY 500 with Omron Profibus Master For Profibus communication user needs the software Cx Profibus You need to enter the password as password default you can also change that The steps for configuration of Profibus network are as follows ...

Page 56: ...Creating Project 51 Doc No UMAN GWY 500 B 0106 REVISION 4 1 First install the GSD file for Profibus slave module View Device Catalogue Install GSD file ...

Page 57: ...Creating Project 52 Doc No UMAN GWY 500 B 0106 REVISION 4 2 Then user should form the network that consists of master and slave module Select the module Add Device to the network ...

Page 58: ...Creating Project 53 Doc No UMAN GWY 500 B 0106 REVISION 4 ...

Page 59: ...Creating Project 54 Doc No UMAN GWY 500 B 0106 REVISION 4 3 Profibus slave module is configured as follows a In Configuration tab configure the Input and Output modules ...

Page 60: ...Creating Project 55 Doc No UMAN GWY 500 B 0106 REVISION 4 b In Parameter tab keep it to common ...

Page 61: ...Creating Project 56 Doc No UMAN GWY 500 B 0106 REVISION 4 c In Group tab assign the group for the slave for global commands ...

Page 62: ...Creating Project 57 Doc No UMAN GWY 500 B 0106 REVISION 4 ...

Page 63: ...Creating Project 58 Doc No UMAN GWY 500 B 0106 REVISION 4 4 Now configure Profibus master module as shown below ...

Page 64: ...Creating Project 59 Doc No UMAN GWY 500 B 0106 REVISION 4 ...

Page 65: ...Creating Project 60 Doc No UMAN GWY 500 B 0106 REVISION 4 You can change the baud rate in Bus Parameter tab In Omron master some area is assigned for Input Input to Master and Output output from master ...

Page 66: ... B 0106 REVISION 4 In case of this project it is CIO3300 for Input and CIO3200 for output The type of PLC and communication port Baud Rate should be specified in Device setup tab Configure Device Type Settings Configure Network Type Settings ...

Page 67: ...e the following in the Device Information Item Description OMRON Corporation This is fixed text indicating the Manufacturer of the PROFIBUSDP Master Unit Description This string will contain the name of the Unit i e CJ1W PRM21 or CS1W PRM21 Firmware Version This string displays the firmware version currently in the PROFIBUS DP Master Unit ...

Page 68: ... 63 Doc No UMAN GWY 500 B 0106 REVISION 4 5 Download the parameters in PLC 6 When The Slave starts communicating with master the COMM led gets on 7 User can watch the area CIO3200 and CIO3300 with help of CX Programmer ...

Page 69: ...add and then click on Next Again click Next Now if you want to change project name you can change otherwise remains as it is and then click on Finish You are getting a window with lots of options Like Simatic 300 station CPU 315 2 DP 1 Name of selected CPU S7 Program etc Now click on Simatic 300 station Now double click on Hardware 02 Now you are getting a window with a name Simatic 300 configurat...

Page 70: ...Creating Project 65 Doc No UMAN GWY 500 B 0106 REVISION 4 03 Then delete the CPU no which is present in a window 0 UR comes under Simatic 300 configuration window 04 You will see a window shown below ...

Page 71: ...o UMAN GWY 500 B 0106 REVISION 4 05 Now install GSD file Path of GSD file C Program Files Gateway 3 11 GWY 500 Profibus Gateway GSD This is the default path The actual path is where the user has installed Gateway Setup Software ...

Page 72: ...7 Doc No UMAN GWY 500 B 0106 REVISION 4 06 Now drag proper CPU Siemens CPU from Hardware Catalog Window to Hardware configuration window Parameter Setting Network Setting 01 Transmission Rate e g 12 Mbps 02 Profile DP 1 ...

Page 73: ...Creating Project 68 Doc No UMAN GWY 500 B 0106 REVISION 4 1 ...

Page 74: ...0 B 0106 REVISION 4 07 Now drag GWY xxx from Hardware Catalog Window to HW configure Window Give a proper address to profibus which should be in between 0 125 because Siemens PLC range is 0 125 whereas VF S11 Toshiba Inverter range is 0 255 ...

Page 75: ...o_31 S7_Pro_31 Name of a file If Catalog window not appears on screen the click a button that is present at the left side of exclamation mark 09 Now drag GWY xxx from Hardware Catalog to Netpro window 10 Click on GWY xxxx which is shown below You are getting a table which is related with GWY xxxx You have to do a program in it 5 GWY xxxxx DP NORM ...

Page 76: ...Creating Project 71 Doc No UMAN GWY 500 B 0106 REVISION 4 Important Note A slot has to be filling up from slot no 1 You can t leave blank slot in between ...

Page 77: ...Creating Project 72 Doc No UMAN GWY 500 B 0106 REVISION 4 11 After completion of program download that program to PLC Siemens PLC ...

Page 78: ...Creating Project 73 Doc No UMAN GWY 500 B 0106 REVISION 4 12 After downloading project to PLC Go to Simatic Manager Window PLC Display Accessible Node ...

Page 79: ...oject 74 Doc No UMAN GWY 500 B 0106 REVISION 4 13 Then Go to PLC Monitor Modify Variables Before it 1st MPI 2 and the click on PLC You get a window whose name is Var_Variable_Table1 2 3 Table1 2 3 Name of a table ...

Page 80: ...ram created in GWY software and program created for Profibus Just observe the three windows which are shown below From these three windows you will easily find out how a program is done and what is relation of being this three windows together 15 After this communication should takes place in between PLC and Toshiba inverter via Profibus Option Card ...

Page 81: ...Applications 76 Doc No UMAN GWY 500 B 0106 REVISION 4 APPLICATIONS In this chapter Possible Applications using GWY 500 B ...

Page 82: ... Modbus Network Modbus Protocol GWY 500 B 50 RPM x10 0 100 A S T R A HMI Software ASTRA by Renu Electronics Modbus Master PLC Profibus Master Drive Motor Profibus DP Protocol PLC PLC Node n Node 1 Node 2 PLC1 Profibus DP Protocol PLC Profibus Master PLC Drive Motor Node n PID Controller Node 1 X Protocol GWY 500 B Node 2 PLC PLC2 Profibus DP Protocol PLC1 X Protocol GWY 500 B Profibus Master ...

Page 83: ...N GWY 500 B 0106 REVISION 4 4 Add I O to your PLC Images not to scale Modbus Protocol Node 1 Node n EAGLE 0800 EAGLE 0800 Eagle Analog I O Example Eagle0800 by Renu Electronics GWY 500 B Profibus DP Protocol PLC Profibus Master ...

Page 84: ...Cable Diagrams Doc No UMAN GWY 500 B 0106 REVISION 4 79 CABLE DIAGRAMS In this chapter Communication Cables for GWY 500 IBM Cable for GWY 500 ...

Page 85: ...DE TOSHIBA VF S11 SIDE 2 mtr Pin 1 2 3 4 5 6 7 8 9 SIGNALS RXD SG CMOS TXD DB9 MALE CMOS Pin 1 2 3 4 5 6 7 8 SIGNALS SG RXD CMOS TXD 8 PIN MODULAR CONNECTOR CMOS DB9 MALE PINOUTS 8 PIN MODULAR CONNECTOR PINOUTS FRONT VIEW R H S VIEW Shield Wire Shield Wire 6 9 1 5 Cable insert end Cable insert end Pin 1 Left side Pin 8 Right side ...

Page 86: ...IBA T1 LINK PORT TO GWY 500 UNIT GWY 500 SIDE TOSHIBA T1 LINK PORT SIDE 2 mtr Pin 1 2 3 4 5 6 7 8 9 SIGNALS TX RX SG TX RX DB9 MALE RS485 Pin YELLOW GREEN BLACK WHITE BLUE SIGNALS RX TX SG RX TX WIRE OUTS SIGNAL FROM PLC DB9 MALE PINOUTS Shield Wire Shield Wire 6 9 1 5 ...

Page 87: ... OMRON MASTER PROFIBUS PORT TO GWY 500 PROFIBUS PORT UNIT GWY 500 SIDE OMRON SIDE 2 mtr SIGNALS B SG A DB9 MALE RS485 DB9 MALE RS485 DB9 MALE PINOUTS Shield Wire Shield Wire to DB9 body ATTACH PLC Pin 1 2 3 4 5 6 7 8 9 Pin 1 2 3 4 5 6 7 8 9 SIGNALS B SG A 6 9 1 5 ...

Page 88: ...IEMENS MASTER PROFIBUS PORT TO GWY 500 PROFIBUS PORT UNIT GWY 500 SIDE SIEMENS SIDE 2 mtr SIGNALS B SG A DB9 MALE RS485 DB9 MALE RS485 DB9 MALE PINOUTS Shield Wire Shield Wire to DB9 body ATTACH PLC Pin 1 2 3 4 5 6 7 8 9 Pin 1 2 3 4 5 6 7 8 9 SIGNALS B SG A 6 9 1 5 ...

Page 89: ...ISION 4 84 10 1 5 NS TO GWY 500 UNIT GWY 500 SIDE NS SIDE 2 mtr DB9 MALE RS232 DB9 MALE RS232 DB9 MALE PINOUTS Shield Wire to DB9 body ATTACH PLC 6 9 1 5 SIGNALS TXD RXD SG Shield Wire Pin 1 2 3 4 5 6 7 8 9 Pin 1 2 3 4 5 6 7 8 9 SIGNALS TXD RXD SG ...

Page 90: ...TECHNOLOGY CONTROLLER 2 mtr Pin 1 2 3 4 5 6 7 8 9 SIGNALS TX RX SG TX RX DB9 MALE RS485 Pin 1 2 3 4 5 6 7 8 SIGNALS RX RX TX TX GND 8 PIN MODULAR CONNECTOR RS485 DB9 MALE PINOUTS 8 PIN MODULAR CONNECTOR PINOUTS 6 9 1 5 Cable insert end Cable insert end Pin 1 Left side Pin 8 Right side FRONT VIEW R H S VIEW Shield Wire Shield Wire ...

Page 91: ...Cable Diagrams Doc No UMAN GWY 500 B 0106 REVISION 4 86 10 1 7 OPTOMUX TO GWY 500 5 1 6 9 RX RX TX TX TX TX RX RX COM1 PLC1 RS232 RS485 CMOS ...

Page 92: ...OGAWA CONTROLLER TO GWY 500 UNIT GWY 500 SIDE YOKOGAWACONTROLLER SIDE 2 mtr Pin 1 2 3 4 5 6 7 8 9 SIGNALS TX RX SG TX RX DB9 MALE RS485 Pin YELLOW GREEN BLACK WHITE BLUE SIGNALS RX TX SG RX TX WIRE OUTS SIGNAL FROM PLC DB9 MALE PINOUTS Shield Wire Shield Wire 6 9 1 5 ...

Page 93: ...EC P 007 00 UNIT GWY 500 SIDE AB SLC SIDE 2 mtr Pin 1 2 3 4 5 6 7 8 SIGNALS TX RX SG TX RX DB9 MALE Pin 1 2 3 4 5 6 7 8 SIGNALS A B SHIELD SG 8 PIN MODULAR CONNECTOR DB9 MALE 8 PIN MODULAR CONNECTOR Cable insert Cable insert Pin 1 Pin 8 FRONT VIEW R H S VIEW A B Shield Wire Shield Wire 6 9 1 5 ...

Page 94: ...LCs TO GWY 500 EC P 027A 00 UNIT GWY 500 SIDE AB MICROLOGIX SIDE 2 mtr Pin 1 2 3 4 5 6 7 8 9 SIGNALS TXD RXD SG DB9 MALE RS232 Pin 1 2 3 4 5 6 7 8 SIGNALS SG RXD TXD MINIDIN 8 PIN MALE RS232 DB9 MALE PINOUTS 8 PIN MINIDIN CONNECTOR PINOUTS Shield Wire Shield Wire 6 9 1 5 6 3 4 1 8 7 5 2 ...

Page 95: ...PORT TO GWY 500 EC P 027B 00 UNIT GWY 500 SIDE AB SLC SIDE 2 mtr SIGNALS TXD RXD SG DB9 MALE RS232 DB9 FEMALE RS232 DB9 MALE PINOUTS DB9 FEMALE PINOUTS 6 9 1 5 Shield Wire Shield Wire to DB9 body ATTACH PLC 9 6 5 1 Pin 1 2 3 4 5 6 7 8 9 Pin 1 2 3 4 5 6 7 8 9 SIGNALS RXD TXD SG ...

Page 96: ...1 12 OMRON CQM1 PLC TO GWY 500 EC P 006B 00 UNIT GWY 500 SIDE OMRON CQM1 SIDE 2 mtr SIGNALS TXD RXD SG DB9 MALE RS232 DB9 MALE RS232 DB9 MALE PINOUTS 6 9 1 5 Shield Wire Shield Wire ATTACH PLC Pin 1 2 3 4 5 6 7 8 9 Pin 1 2 3 4 5 6 7 8 9 SIGNALS EARTH TXD RXD SG ...

Page 97: ...06A 00 UNIT GWY 500 SIDE OMRON CMOS SIDE 2 mtr SIGNALS RXD SG TXD CMOS DB9 MALE CMOS OMRON 20 PIN CONNECTOR CMOS DB9 MALE PINOUTS Shield Wire Shield Wire Pin 1 2 3 4 5 6 7 8 9 Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 SIGNALS RXD TXD CMOS SG OMRON OMRON OMRON OMRON OMRON TM C200H CN422 6 9 1 5 ...

Page 98: ...BM Cables 10 2 1 IBM CABLE FOR GWY 500 2 mtr SIGNALS TXD RXD SG DB9 MALE RS232 DB9 FEMALE RS232 DB9 MALE PINOUTS DB9 FEMALE PINOUTS Shield Wire Shield Wire Pin 1 2 3 4 5 6 7 8 9 Pin 1 2 3 4 5 6 7 8 9 SIGNALS RXD TXD SG PC SIDE IBM UNIT GWY 500 SIDE 9 6 5 1 6 9 1 5 ...