Hardware description
18/166
4.3.3
EDG (Edge) LED
The Edge LED (labelled
EDG
, see position
(4)
page 12]) indicates the configuration and operating states of
the IO-Link sensor(s).
LED
Color
State
Meaning
EDG
Duo LED yellow/green
(off)
Off
IO-Link functionality has not been started yet.
(yellow)
Fast blinking at 5
Hz
IO-Link functionality has been started and is in
auto-configuration state.
(green)
Slow blinking at
1 Hz
Auto-configuration of IO-Link sensors has
failed (e.g. no IODD file found). Manual
configuration of IO-Link sensors is required
(e.g. upload of IODD file via IO-Link
Configurator in Local Device Manager).
(green)
On
IO-Link sensor configuration and
communication ok.
(yellow/
green)
Alternating at 1
Hz
IO-Link setup/configuration change during
runtime detected. Maintenance may be
required using the IO-Link Configurator in Local
Device Manager.
Table 12: EDG (Edge) LED
4.3.4
Power supply LEDs
The
1L
and
2L
LEDs (see positions
(18)
and
(16)
in section
page 12]) indicate the state of the supply voltage at
X21
.
1L: Standard 24 V DC supply voltage U
1L
2L: Auxiliary 24 V DC supply voltage U
2L
(not used)
Note:
Although the LED and the pins for the auxiliary load circuit 2L are
implemented on the device, the sensorEDGE does not need or use
any auxiliary supply voltage (U
2L
),
LED
Color
State
Meaning
1L
Duo LED green/red
(green)
On
U
1L
standard supply voltage is ok (voltage is between
18 V and 30 V)
(red)
On
U
1L
standard supply voltage is too low (voltage is
below 18 V)
(red)
Fast blinking
at 4 Hz
U
1L
standard supply voltage is too high (voltage is
above 30 V)
Off
Off
No U
1L
standard supply voltage connected or below
11 V
2L
Duo LED green/red
Note
: Red LED is not connected
(green)
On
U
2L
auxiliary supply voltage is connected (not needed
or used by the device)
Off
Off
No U
2L
auxiliary supply voltage connected
Table 13: 1L and 2L LEDs
netFIELD sensorEDGE | User manual
DOC200601UM01EN | Revision 1 | English | 2021-09 | Released | Public