SRX240 Services Gateway Quick Start

Follow the instructions in this quick start to connect the SRX240 Services Gateway to 
your network. For details, see the 

SRX240 Services Gateway Hardware Guide

 at 

http://www.juniper.net/techpubs/en_US/release-independent/junos/information-products/
pathway-pages/srx-series/product/index.html.

SRX240 Services Gateway Front Panel

SRX240 Services Gateway Back Panel

SRX240 Services Gateway Models

The following models of the SRX240 Services Gateway are available:

NOTE: 

On the SRX240H-POE,SRX240H2-POE, SRX240H-POE-TAA, and 

SRX240H2-POE-TAA models, Power over Ethernet (PoE) of a maximum of 150 watts is 
supported on all the16 ports (0/0 through 0/15).

Connecting and Configuring the SRX Series Services Gateway

Follow these instructions to connect and set up the SRX240 Services Gateway. The 
LEDs on the front of the device indicate the status of the device.

Configuration Overview

The SRX240 Services Gateway requires the following basic configuration settings to 
function:

Interfaces must be assigned IP addresses.

Interfaces must be bound to zones.

Policies must be configured between zones to permit or deny traffic.

Source NAT rules must be set.

The device has the following default configuration set when you power it on for the first 
time. To use the device, you do not need to perform any initial configuration.

Callout Description

Callout

Description

1

Mini-PIM slots

5

Console port 

2

Power button

6

Gigabit Ethernet (0/0 to 0/15) ports

3

LEDs (ALARM, POWER, 
STATUS, HA, mPIM)

7

USB ports

4

Reset Config button

Callout

Description

Callout

Description

1

Cable tie holder

3

Grounding point

2

Power supply input

g037516

1

2

6

7

3

4

5

1

1

1

g037502

1

2

3

Device

DDR Memory

Power over Ethernet

SRX240B

512 MB

No

SRX240B2

1 GB

No

SRX240H

1 GB

No

SRX240H2

2 GB

No

SRX240H-DC

1 GB

No

SRX240H2-DC

2 GB

No

SRX240H-POE

1 GB

Yes

SRX240H2-POE

2 GB

Yes

SRX240H-TAA

1 GB

No

SRX240H2-TAA

2 GB

No

SRX240H-POE-TAA

1 GB 

Yes

SRX240H2-POE-TAA

2 GB

Yes

Summary of Contents for SRX240B

Page 1: ...device Configuration Overview The SRX240 Services Gateway requires the following basic configuration settings to function Interfaces must be assigned IP addresses Interfaces must be bound to zones Policies must be configured between zones to permit or deny traffic Source NAT rules must be set The device has the following default configuration set when you power it on for the first time To use the ...

Page 2: ...RJ 45 cable Ethernet cable from the port labeled CONSOLE to the supplied DB 9 adapter which then connects to the serial port on the management device serial port settings 9600 8 N 1 N If you are using this method to connect proceed with the CLI configuration instructions in the Getting Started Guide for the Branch SRX Series at http www juniper net techpubs en_US release independent junos informat...

Page 3: ...or your services gateway IMPORTANT Ensure that you have configured the IP address root authentication and default gateway before you apply the configuration NOTE All fields marked with an asterisk are mandatory All network and management access settings are optional If you have followed Method 1 of Task 4 Obtaining a Dynamic IP Address on Your Services Gateway skip all the other steps and go to Ta...

Page 4: ...ins gracefully shutting down the operating system Press the Power button again to power on the device Forced shutdown Press the Power button and hold it for 10 seconds The device immediately shuts down Press the Power button again to power on the device You can reboot or halt the system in the J Web interface by selecting Maintain Reboot NOTE Use the graceful shutdown method to halt power off or r...

Reviews: