Technical data
149/166
Category
Parameter
Value
Electromagnetic
compatibility (EMC)
Radio Interference Field
Strength Emission
DIN EN 55016-2-3 / BS EN 55016-2-3
Radiated Field Immunity
DIN EN 61000-4-3 / BS EN 61000-4-3
Conducted Disturbances
Immunity
DIN EN 61000-4-6 / BS EN 61000-4-6
Radio Interference
Voltage Emission
DIN EN 55016-2-1 / BS EN 55016-2-1
ESD contact discharge
DIN EN 61000-4-2 / BS EN 61000-4-2
4 kV
Burst
DIN EN 61000-4-4 / BS EN 61000-4-4
Surge
DIN EN 61000-4-5 / BS EN 61000-4-5
Mechanical tests
Vibration sinusoidal
DIN EN 60068-2-6:2008 (including monitoring for contact breaks
according to DIN EN 60512-2-5:2004)
Shock
DIN EN 60068-2-27:2010 (including monitoring for contact
breaks according to DIN EN 60512-2-5:2004)
Free fall
DIN EN 60068-2-31:2009
Approvals
UL
In preparation
Conformity declarations
CE
Yes
UKCA
Yes
RoHS
Yes
REACH
Yes
Ethernet LAN interface
Type
10/100 MBit/s Ethernet port (eth0)
Connector
M12, D-coded, female, 4-pin.
Recommended tightening torque of locking screw: 0.4 – 0.6 Nm
IO-Link
Type
IO-Link Master, Class A, 8 ports
Connector
8 x M12 A-coded, female, 5-pole
Recommended tightening torque of locking screw: 0.4 – 0.6 Nm
Maximum cable length: 20 m.
LED indicators
SYS
(green/yellow)
“System” status LED of the communication controller
Wi-Fi/Bluetooth
(blue)
Currently without function (reserved for future use)
EDG
(red/green)
“Edge” LED indicating configuration and operating states of the
IO-Link sensors
CLD
(red/green)
“Cloud” LED indicating connectivity with the Internet/cloud
RUN
(red/green)
Currently without function (reserved for future use)
ERR
(red/green)
Currently without function (reserved for future use)
LINK
(green)
Ethernet Link status
ACT
(yellow)
Ethernet Activity status
1L
(red/green)
Indicates supply voltage status
2L
(green)
Indicates supply voltage status of second load circuit (U
2L
).
Note
: The sensorEDGE does not need or use auxiliary supply
voltage (U
2L
), even though the 2L LED and the pins for the 2L
auxiliary load circuit are implemented on the device.
8 x
A
(red/green/yellow)
Status of the IO-Link port
(Note: Yellow is produced by switching red and green duo LED
on at the same time)
8 x
B
(red/green/yellow)
Not used
Table 39: Technical data sensorEDGE
netFIELD sensorEDGE | User manual
DOC200601UM01EN | Revision 1 | English | 2021-09 | Released | Public
© Hilscher 2021