DS-73xxHUI-K4, DS-73xxHQI-K4, DS-90xxHUI-K8 DVR User Manual
UM DS-73xxHUI-K4 DS-73xxHQI-K4 DS-90xxHUI-K8 092017NA
49
•
Full Screen Monitoring Dwell Time:
Sets
the time in seconds to show the alarm
event screen.
4.
Set the camera order.
1)
Click the
View
tab and select
Video Output Interface
from the drop-down list.
Figure 54,
Live View Camera Order
2)
Click a window to select
it
, then double-click a camera to display in the camera list.
Setting an ‘X’ means the window will not display any camera.
3)
You can also click
to start live view of all channels in order and click
to stop
live view of all channels. Click
or
to go to the previous or next page.
4)
Click
Apply
.
If the sum of the analog and IP channels exceeds 25, up to 32-window division mode
is supported for the VGA/HDMI1 output.
3.6
Manual Video Quality Diagnostics
Purpose
The video quality of the analog channels can be diagnosed manually and you can view the
diagnostic results from a list.
1.
Go to Menu > Manual > Manual Video Quality Diagnostics.
Figure 55,
Video Quality Diagnostics