The zone activates all the time. It alarms when the event you
defined does happen throughout a configurable period. It is
usually used in places equipped with magnetic contacts
(e.g., fire hydrant box's door).
Shield Zone
Alarms will not be activated when the zone is triggered or
tampered. It is usually used to disable faulty detectors .
5. Enable Stay Arming Bypass, Doorbell, or Mute according to
your actual needs.
Note
Some zones do not support the function. Refer to the actual
zone to set the function.
6. Enable Link Wireless Detector , input the serial No., and set
the linked camera No.
Note
868 Devices do not support inputting serial No.
7. Click OK.
Note
After setting the zone, you can enter Status → Zone to view
the zone status.
Alarm Schedule
You can set the delayed time duration for the delayed zone and
the delayed time to exit the zone. You can also set the alarm
schedule. The zone will be armed/disarmed according to the
configured time schedule.
Steps
1. Click System → Schedule & Timer to enter the Schedule &
Timer page.
Figure 1-18 Schedule & Timer Page
2. Set time duration of Delay 1, Delay 2, or Exit Delay
respectively.
Delay 1/Delay 2
18