LineIn0 Wiring with Line Trigger Device
PWR 48V
VCC
Device Power
Differential Input
0+
Differential Input 0- Hang
Device Power
Ground
Common
Ground
GND of PWR
GND of VCC
Line Trigger
Device
Line Trigger
Device Power
Line Trigger
Signal
Line Trigger
Device Power Ground
Figure 4-22 LineIn0 Wiring with Line Trigger Device
4.2.4 Output Signal Wiring
The device can output signals to external devices via its I/O interface. This section introduces how
to wire the device to different types of external devices.
Note
●
Here we take LineOut0 as an example to introduce the input signal wiring.
●
Output signal wiring may differ with different types of external devices.
PNP Device
Opto-isolated
Output
Output Signal
Ground
PWR 48V
Device Power
Device Power
Ground
GND of PWR
GND of VCC
VCC
PNP Power
Signal Line
PNP Power
Ground
PNP Device
Figure 4-23 Output Signal Connects PNP Device