56
Output Retrans Enable
If this parameter is enabled, the data is allowed to retransmit to FTP server, and should set specific
value in
Output Retrans Number
.
Note
If data retransmission is still failed after the times allowed for data retransmission is reached, the
retransmission will be discarded.
FTP Transmission Conditions
It sets the condition to upload the data outputted by the device to FTP server.
All
refers to upload
the data always.
Read Barcode
refers to upload the data only when the barcode is read by the
device.
No Read Barcode
refers to upload the data only when no barcode is read by the device.
FTP Transmission Result Contain
It selects contents to upload to the FTP server.
Just Result
refers to only upload the content of
the code.
Just Picture
refers to only upload the code picture.
Result and Picture
refers to upload
both the content of the code and the picture.
FTP Image Format
It sets the format of the picture uploaded to FTP server.
Note
The device currently support JPG format only.
FTP File Default Name
It refers to the default name of the file uploaded to FTP server. You can set it according to actual
condition.
FTP File Separator
It refers to the separator that separates file name. You can set it according to actual condition.
FTP File Name Contain Package Number Enable
If this parameter is enabled, the name of the file uploaded to FTP server will contain the
package ID.
FTP File Name Contain Barcode Number Enable
If this parameter is enabled, the name of the file uploaded to FTP server will contain the
number of the barcode.
FTP File Name Contain FTP Timestamp Type
If this parameter is enabled, you can select different types of timestamp.