ID7000 Series Smart Code Reader User Manual
33
9.1.2 Set Light Source
You can select light type, and set related parameters in the light interface.
Note
●
Light source parameters may differ by device models.
●
Make sure you have selected the device to be set in
Device Connection
before setting light
source parameters.
You can set the duration, delay time and precharge time of the light source when selecting
External
Lighting
as
Light Type
.
Lighting Out Duration
It sets the lighting duration and the unit is μs.
Lighting Out Delay Time
It sets
the delay time for lighting after exposure and the unit is μs.
Line Out Ahead Time
It determines how earlier the light source starts lighting before
exposure and the unit is μs.
Figure 9-2 Set Light Source
9.2 Code Algorithm Settings
The device supports reading multiple types of 1D code and 2D code, and you can add and set code
parameters via the client software.
9.2.1 Add Code
Adding code before you set code parameters via the client software. In
Algorithm Settings
, you can
add different types of codes according to actual demands.
In
Algorithm Settings
, click
Add Barcode
, select the types of codes to be read, and set the
1D Code