ID7000 Series Smart Code Reader User Manual
45
frequency signal as the
device’s
trigger signal.
9.4 Signal Output Settings
9.4.1 Select Output Signal
The
device’s output signal can control external devices like PLC, flashing light, etc. Click
I/O Control
Settings
→
Output
→
Line Out Selector
to select output signal.
Note
●
The specific output signals may differ by device models.
●
The LineOut2 cannot be used as the output signal because it is the output port of controlling light
source mode.
Figure 9-17 Select Output Signal
9.4.2 Set Event Source
Note
The event source parameters may differ by device model.
The device supports outputting different trigger signals according to the event source you select.
Click
I/O Control Settings
→
Output
→
Line Out Activation Event
to select event source. The device
supports following event sources, including
Acquisition Start Active
,
Acquisition Stop Active
,
Exposure Start Active
,
Soft Trigger Active
,
Timer Active
,
No Code Read
,
Read Success
, and
Light
Strobe Long
.
Note
Off
refers to no event source.
Acquisition Start Active
If acquisition starts, the output signal will be triggered.