background image

 

AY-x55 

Anti-Vandal Piezoelectric PIN 
Reader 

Installation and Programming Manual 

 

Models:

 

AY-S55 
AY-T55 
AY-T55B

 

AY-S55 

AY-T55 

AY-T55B 

Summary of Contents for AY-S55

Page 1: ...AY x55 Anti Vandal Piezoelectric PIN Reader Installation and Programming Manual Models AY S55 AY T55 AY T55B AY S55 AY T55 AY T55B ...

Page 2: ...al property rights covering the subject matter in this manual TEXTS IMAGES AND ILLUSTRATIONS INCLUDING THEIR ARRANGEMENT IN THIS DOCUMENT ARE SUBJECT TO THE PROTECTION OF COPYRIGHT LAWS AND OTHER LEGAL RIGHTS WORLDWIDE THEIR USE REPRODUCTION AND TRANSMITTAL TO THIRD PARTIES WITHOUT EXPRESS WRITTEN PERMISSION MAY RESULT IN LEGAL PROCEEDINGS The furnishing of this manual to any party does not give t...

Page 3: ...structions 10 3 2 Wiring Instructions 11 4 Functionality 12 4 1 Transmit Mode 12 4 2 Programming the AY x55 12 4 2 1 Entering Programming Mode 13 4 2 2 Exiting Programming Mode 14 4 2 3 Selecting Keypad Transmission Format 14 4 2 4 Changing the Programming Code 20 4 2 5 Changing the Facility Code 21 4 3 Setting the Backlight 21 4 4 Return to Factory Default Settings 22 4 5 Replacing a Lost Program...

Page 4: ...List of Figures iv AY x55 Family Installation and Programming Manual List of Figures Figure 1 Drilling Mounting Holes 10 ...

Page 5: ...List of Tables AY x55 Family Installation and Programming Manual v List of Tables Table 1 Wiring Colors 11 Table 2 Reader Programming Menus 13 Table 3 Keypad Transmission Format Option Number 15 ...

Page 6: ...future options Therefore not all functions described in this manual may be available in the specific system and or product configuration you purchased Incorrect operation or installation or failure of the user to effectively maintain the system relieves the manufacturer and seller from all or any responsibility for consequent noncompliance damage or injury The text images and graphics contained in...

Page 7: ... 1 1 Key Features The key features for the AYC Q65 are Built in high sensitivity piezoelectric keypad Programmable backlit keypad AY T55B only Programmable keypad transmission format Built in case and back tamper Tamper output and LED control Input Programmable Facility code Two tri colored LEDs Internal buzzer provides audible interface feedback 1 2 Box Content Before beginning verify that all of...

Page 8: ...ogramming Manual 1 3 Ancillary Equipment The following equipment is required to complete your installation Compatible host controller Power supply 5 to 16 VDC from a regulated power supply Rosslare accessories can be found on www rosslaresecurity com ...

Page 9: ... Max 180 mA Tamper Output Open collector active low max sink current 32 mA LED Control Input Dry contact N O Environmental Characteristics Operating Temp Range 31 C to 63 C 25 F to 145 F Operating Environment Suitable for outdoor use meets IP65 Operating Humidity Range 0 to 95 non condensing Dimensions Height x Width x Depth 150 x 42 x 27 mm 5 91 x 1 65 x 1 06 in 120 x 65 x 27 mm 4 72 x 2 56 x 1 0...

Page 10: ...n the back of the metal cover specifically aligned for the US Gang Box marked as A in Figure 1 For a four screw custom installation there are four indicators on the back marked as B in Figure 1 Figure 1 Drilling Mounting Holes AY T55 AY S55 2 Route the interface cable from the reader to the controller see Section 3 2 A linear type power supply is recommended 3 Screw the AY x55 back cover to its mo...

Page 11: ...ing the cable jacket back 2 5 cm 1 and strip the wire 2 5 cm 1 2 Prepare the controller cable by cutting the cable jacket back 2 5 cm 1 and strip the wire 2 5 cm 1 3 Splice the unit s pigtail wires to the corresponding controller wires and cover each connection Refer to Table 1 and to the wiring diagrams provided on the following pages Table 1 Wiring Colors Color Output Red VDC Black Ground White ...

Page 12: ...entry is being transmitted the Transmit LED flashes green Keyboard data can be sent via one of eight different keypad transmission formats see Section 4 2 3 4 2 Programming the AY x55 Programming the AY x55 is done solely via the unit s keypad driven Programming Menu System During the AY x55 s manufacturing process certain codes and settings are pre programmed These settings are called the default...

Page 13: ...gand 26 Bit Single Key 3x4 Matrix Keypad 1 to 8 Keys BCD Clock Data Single Key Wiegand 4 Bit 3 Changing the Programming Code 1234 4 Changing the Facility Code 0 6 Backlight Options AY T55B only Off On default Off until key press when on for 10 seconds Dimmed until key press when on for 10 seconds 0 Return to Factory Default Settings 4 2 1 Entering Programming Mode To reach the Programming Menu Sys...

Page 14: ...Program LED turns off This indicates that the unit has returned to Transmit mode Wrong entries may reset the reader back to Transmit mode While in Programming mode if no key is pressed for 30 seconds the unit exits Programming mode and returns to Transmit mode 4 2 3 Selecting Keypad Transmission Format The AY x55 has eight different keypad transmission formats See Section 4 2 3 1 for more informat...

Page 15: ... time When using the keypad transmission format 1 to 8 keys BCD Clock Data Option 8 an additional input is required to specify the number of keys in the PIN code 4 2 3 1 Keypad Transmission Format Option Number Table 3 presents the eight different keypad transmission formats Table 3 Keypad Transmission Format Option Number Keypad Transmission Format Option Number Single Key Wiegand 6 Bit Rosslare ...

Page 16: ...100 1 1 1011 1 B in Hexadecimal 5 1 0101 0 0 1100 1 C in Hexadecimal Option 2 Single Key Wiegand 6 Bit Nibble and Parities Each key press immediately sends 4 bits with 2 parity bits added even parity for the first 3 bits and odd parity for the last 3 bits 0 0 0000 1 6 1 0110 0 1 0 0001 0 7 1 0111 1 2 0 0010 0 8 1 1000 1 3 0 0011 1 9 1 1001 0 4 1 0100 1 1 1010 0 A in Hexadecimal 5 1 0101 0 1 1011 1...

Page 17: ...he fourth key press of the 4 digit PIN code the data is sent across the Wiegand Data lines as binary data in the same format as a 26 Bit Card If or are pressed are pressed during PIN code entry the keypad clears the PIN code entry buffer generate a beep and is ready to receive a new 4 digit keypad PIN code If the entry of the 4 digit keypad PIN code is disrupted and no number key is pressed within...

Page 18: ...generates a beep and is ready to receive a new 5 digit keypad PIN code If the entry of the 1 to 5 digit keypad PIN code is disrupted and a number key or is not pressed within 5 seconds the keypad clears the PIN code entry buffer generates a medium length beep and is ready to receive a new 1 to 5 digit keypad PIN code EP FFFF FFFF AAAA AAAA AAAA AAAA OP Where EP Even parity for first 12 bits OP Odd...

Page 19: ...or Clock Data formats active An optional interface board must be used between the AY x55 and the host system Each key press is immediately sent on DATA0 as an ASCII character at a baud rate of 9600 bits per second When a key is pressed DATA1 is pulled low until the key is released at which point DATA1 is set to high This allows the controller to detect the duration of the key press The MD P64 inte...

Page 20: ...s a beep and is ready to receive a new keypad PIN code If the entry of the digit keypad PIN code is disrupted and a number key or is not pressed within 5 seconds the keypad clears the PIN code entry buffer generates a medium length beep and is ready to receive a new keypad PIN code When using the keypad transmission format 1 to 8 keys BCD Clock Data Option 8 an additional input is required to spec...

Page 21: ... 3 digit code you wish to set as the Facility code The system returns to Transmit mode You hear three beeps The Program LED turns off and the Transmit LED turns red The Facility code can be in the range of 000 to 255 The default Facility code is 0 4 3 Setting the Backlight 1 Enter Programming mode 2 Press 6 to enter Menu 6 The Transmit LED turns red 3 Enter the appropriate option number for the ba...

Page 22: ...be very careful before using this command This erases the entire memory and return all codes to their factory default setting 1 Enter Programming mode 2 Press 0 to enter Menu 0 The Transmit and Program LEDs flash red 3 Enter your 4 digit programming code If the Programming code is valid all memory is erased You hear three beeps and the controller returns to Normal mode If the Programming code is i...

Page 23: ... code is forgotten the AY x55 can be reprogrammed in the field using the following instructions 1 Remove power from the reader 2 Activate tamper by removing the reader from the wall or removing the reader s case 3 Apply power to the reader 4 You now have 10 seconds to enter Programming mode using the factory default Programming code 1234 ...

Page 24: ...ual A Limited Warranty The full ROSSLARE Limited Warranty Statement is available in the Quick Links section on the ROSSLARE website at www rosslaresecurity com Rosslare considers any use of this product as agreement to the Warranty Terms even if you do not review them ...

Page 25: ...osslaresecurity com Europe Rosslare Israel Ltd Rosh HaAyin Israel Tel 972 3 938 6838 Fax 972 3 938 6830 support eu rosslaresecurity com Latin America Rosslare Latin America Buenos Aires Argentina Tel 54 11 4001 3104 support la rosslaresecurity com China Rosslare Electronics Shenzhen Ltd Shenzhen China Tel 86 755 8610 6842 Fax 86 755 8610 6101 support cn rosslaresecurity com India Rosslare Electron...

Reviews: