background image

SYUR03N-U1 

UHF TCP/IP fixed Reader 

Manual 

 

 

 

 

 

 

Version 01.02

 

2016/05/24 

Summary of Contents for SYUR03N-U1

Page 1: ...SYUR03N U1 UHF TCP IP fixed Reader Manual Version 01 02 2016 05 24 ...

Page 2: ...and Wiegand 1 Wiegand output RS485 baud rate 19 200 bits sec 4 800 460 800 Ethernet 10M 100M Ethernet Port Wi Fi 802 11 b g n Indication LED Beeper Extend 2W Speaker DI DO 4 DI 4 RELAY Protocols EPC Class 1 Gen 2 ISO 18000 6C Built in antenna 8 dbi circularly polarized antenna Read range Up to 6 m depends on tag s antenna Optional extend module Xtive RFID module 13 56MHz HF RFID module Bluetooth m...

Page 3: ...SYUR03N UHF TCP IP fixed Reader Operation Manual 2 II Wiring Diagram ...

Page 4: ...eration Manual 3 III Network Parameter Setting 1 Execute NET_Discover_V0110 exe and press to search SYUR03N product 2 Factory default IP is 192 168 1 101 User can check the MAC address from product sticker with IP to confirm the device ...

Page 5: ...SYUR03N UHF TCP IP fixed Reader Operation Manual 4 3 Double click IP 192 168 1 101 to open the web configure page http 192 168 1 101 Default login ID Password admin admin ...

Page 6: ... as the following User can modify Net Mode and other parameters If device cannot communicate properly after setting user can reset NET module via Micro USB Communication Parameter Factory Default Serial Configure 230400 8 n 1 Serial Framing Length 1050 Locale Remote Port Number 5001 ...

Page 7: ...Wi Fi AP Wi Fi client Default Ethernet DHCP Wi Fi AP mode ETH SERIAL Ethernet only Factory Default WIFI CLIENT SERIAL Wi Fi client mode WIFI AP SERIAL Wi Fi AP mode 1 ETH SERIAL Factory default is ETH SERIAL Standard TCP IP Reader When user modify the IP and click on Apply button device will reboot and apply the setting after 30 seconds ...

Page 8: ...twork Scan User can scan AP in range of SYUR03N and select one to connect But user cannot scan the AP after changing default network mode Ethernet only to Wi Fi Client SYUR03N need to power off on to enable the scan function Encrypt Type Select Encrypt type for AP connection Password Enter password for AP IP Type DHCP is default mode If user has to setup a static IP please select Static ...

Page 9: ...less Access Point for client device to communicate This mode is usually for setting device SSID Setup device s SSID Encrypt Type Select Encrypt Type for the AP Password Setting device s Wi Fi password IP address Setting device s Wi Fi IP address Subnet Mask Setting device s Wi Fi subnet mask ...

Page 10: ...CP IP fixed Reader Operation Manual 9 4 Default mode Ethernet DHCP Wi Fi AP mode It s Dual Mode Ethernet and Wi Fi AP but Ethernet only support DHCP SSID Setup device s SSID Password Setting device s Wi Fi password ...

Page 11: ...on Manual 10 V USB Connection Setup SYUR03N parameter via micro USB 1 Install USB driver CDC_USB_Driver_VCP_V1 4 0_Setup exe 2 System will generate a virtual COM port For example Check port in device manager below picture is COM 3 Micro USB ...

Page 12: ...ually The driver is saved in the folder that is same as following 3 Get device Model information and serial number by using V7 Tools with correct COM port or TCP connection 4 V7 Tools also provides Ethernet mode User only needs to fill in correct IP and Port and click to setup 2 3 4 1 ...

Page 13: ...nitial Restore device to factory default It is NOT including network setting NET Initial 6 sec Restore network parameter of device to default mode User has to setup by referring the following information after restore device to factory default Communication Parameter Factory Default Serial Configure 230400 8 n 1 Serial Framing Length 1050 Locale Remote Port Number 5001 ...

Page 14: ...P fixed Reader Operation Manual 13 2 Reader Set Interface Setup reader s communication interface Default is Wiegand RS485 3 DI DO SYUR03 support 4 digital inputs and 4 relay outputs Click auto test to test DI DO command ...

Page 15: ... read data s byte ID Reverse Reverse read data Addr Setup auto read data s address Start Setup auto read data s address start byte Same Same card time Default is 50 50 x 0 1 5 seconds Reader power Setup UHF RFID power 2 25 dbm to control reader s read range Frequency Range Setup UHF frequency range for different RF regulation Country Frequency range US 902 928 MHz TW 922 928 MHz CN 920 925 MHz CN2...

Page 16: ...SYUR03N UHF TCP IP fixed Reader Operation Manual 15 VII SYUR03N Controller extend slave reader Extend slave reader via RS 485 1 Connect RS485 wire 4R to 4R 4R to 4R ...

Page 17: ...der Operation Manual 16 2 Select READER tab to setup interface to RS485 3 Check controller and reader s RS485 communication rate are the same Default is 64 bits 4 Select 86 Serial tab to setup Controller mode and RS485 Master Mode ...

Reviews: