• Verify that an Intel Xeon 61XXF processor is installed in the processor socket 1.
• Verify that the server has at least 32 GB memory capacity.
• Make sure that you have a T-15 Torx screwdriver available.
Procedure
1.
2.
Disconnect all peripheral cables from the server.
3.
Remove the server from the chassis
on page 28.
4.
on page 30.
5.
Remove the secondary riser cage
on page 33.
6.
Do one of the following:
•
Remove the primary riser blank
on page 35
•
on page 36
7.
Remove the primary riser slot blank.
8.
Connect the IFP and sideband cables to the OPA adapter.
9.
Install the OPA adapter in the primary riser slot. Make sure that the board is firmly seated in the slot.
10. Install the primary riser cage
on page 37.
11.
Connect the OPA adapter IFP cable:
a.
Lift the IFP cable retaining latch.
98
Hardware options installation