Description
Chassis
Fan configuration
Number of drives
supported by the
server
Maximum inlet
ambient
temperature
Apollo r2800
Gen10 Chassis
(24 SFF
backplane with
SAS expander)
Redundant and
nonredundant
0 to 24 drives
35°C (95°F)
Apollo r2800
Gen10 Chassis
(16 NVMe
backplane)
Redundant and
nonredundant
0 to 8 drives
35°C (95°F)
The drive capacity must be less than 10 TB.
The drive capacity must be greater than or equal to 10 TB.
If the component is installed in server 1, and the server is installed in the Apollo r2200 Gen10 Chassis, drive blanks
must be installed in drive bays 1-2 and 1-10. Similarly, if the component is installed in server 3, and the server is
installed in the Apollo r2200 Gen10 Chassis, drive blanks must be installed in drive bays 3-2 and 3-10. For more
information, see
Installing drive blanks and thermal bezel blanks for components with thermal limitations
on
page 23.
PCIe accelerators
Chassis
Fan configuration
Number of drives
supported by the server
Maximum inlet
ambient temperature
Apollo r2200 Gen10
Chassis
(12 LFF backplane)
Redundant and
nonredundant
30°C (86°F)
30°C (86°F)
35°C (95°F)
Apollo r2600 Gen10
Chassis
(24 SFF or 16 SFF
+ 8 NVMe
backplane)
Redundant and
nonredundant
0 to 10 drives
35°C (95°F)
Apollo r2800 Gen10
Chassis
(24 SFF backplane
with SAS expander)
Redundant and
nonredundant
0 to 24 drives
35°C (95°F)
Apollo r2800 Gen10
Chassis
(16 NVMe
backplane)
Redundant and
nonredundant
0 to 8 drives
35°C (95°F)
The drive capacity must be less than 10 TB.
The drive capacity must be greater than or equal to 10 TB.
Specifications
171