Description
Chassis
Fan
configuration
Number of drives
supported by the server
Maximum inlet
ambient
temperature
Apollo r2800
Gen10 Chassis
(24 SFF
backplane with
SAS expander)
Redundant and
nonredundant
0 to 24 drives
25°C (77°F)
Apollo r2800
Gen10 Chassis
(16 NVMe
backplane)
Redundant and
nonredundant
0 to 8 drives
28°C (82.4°F)
CNA
Apollo r2200
Gen10 Chassis
(12 LFF
backplane)
Redundant and
nonredundant
Optical cable: Not
supported
Copper cable: 30°C
(86°F)
Optical cable: Not
supported
Copper cable: 28°C
(82.4°F)
Optical cable:
28°C (82.4°F)
Copper cable: 35°C
(95°F)
Apollo r2600
Gen10 Chassis
(24 SFF or 16
SFF + 8 NVMe
backplane)
Redundant and
nonredundant
0 to 10 drives
Optical cable:
28°C (82.4°F)
Copper cable: 35°C
(95°F)
Apollo r2800
Gen10 Chassis
(24 SFF
backplane with
SAS expander)
Redundant and
nonredundant
0 to 24 drives
Optical cable:
25°C (77°F)
Copper cable: 35°C
(95°F)
Apollo r2800
Gen10 Chassis
(16 NVMe
backplane)
Redundant and
nonredundant
0 to 8 drives
Optical cable:
28°C (82.4°F)
Copper cable: 35°C
(95°F)
The drive capacity must be less than 10 TB.
The drive capacity must be greater than or equal to 10 TB.
164