System battery replacement
System battery information
The server contains an internal lithium manganese dioxide, a vanadium pentoxide, or an alkaline battery
that provides power to the real-time clock. If this battery is not properly handled, a risk of the fire and
burns exists. To reduce the risk of personal injury:
• Do not attempt to recharge the battery.
• Do not expose the battery to temperatures higher than 60°C (140°F).
• Do not disassemble, crush, puncture, short external contacts, or dispose the battery in fire or water.
• If the server no longer automatically displays the correct date and time, then replace the battery that
provides power to the real-time clock. Under normal use, battery life is 5 to 10 years.
Removing and replacing the system battery
Procedure
1.
on page 23.
2.
Disconnect all peripheral cables from the server.
3.
Remove the server from the chassis
on page 28.
4.
on page 30.
5.
Remove the secondary riser cage
6.
remove the primary PCI riser cage
7.
Locate the battery on the system board
8.
Slightly push the metal tab, and then remove the system battery from the socket.
9.
Slightly push the metal tab, and then install the new system battery in the socket.
132
System battery replacement