12.
If you have installed a Smart Array P-class Gen10 controller,
connect the storage controller
backup power cable to the riser board
.
13. Install the secondary riser cage
on page 34.
14. Connect the controller Mini-SAS cables to the bayonet board
on page 31.
16. Install the server into the chassis
on page 29.
17.
Connect all peripheral cables to the server.
18.
To enable HPE Smart Array SR SmartCache or HPE Smart Array MR CacheCade in a Smart Array
P-class Gen10 controller, install an energy pack.
SmartCache and CacheCade enable solid-state drives to be used as caching devices for hard drive
media. These features accelerate access to frequently used data by caching hot data from the hard
drives onto the solid-state drives.
For more information, see the chassis user guide on the Hewlett Packard Enterprise website
(
https://www.hpe.com/info/Apollo2000-Gen10-docs
).
19. Configure the HPE Smart Array Gen10 controller
.
The installation is complete.
Installing the HPE Smart Array P824i-p MR Gen10 Controller
The HPE Smart Array P824i-p MR Controller is supported in the r2600 chassis where it supports 12
drives per node. Install two P824i-p controllers to support the maximum 24 drive configuration. P824i-p
controller is supported in the secondary riser slot 3 transfer board.
CAUTION:
The maximum inlet ambient temperature for most components installed in the system is
35°C (95°F). Some components, however, are subject to thermal limitations depending on the
chassis model and the fan configuration. There are some hardware configurations where it is
necessary to limit the number of drives installed in the chassis. For more information, see
.
84
Hardware options installation